Installation Guide

Troubleshooting (cont.)
Bath System
Symptoms Probable Causes Recommended Action
12. Water spillage or damage
observed under the bath.
A. Drain or overflow leaking. A. Repair or replace the drain
assembly according to the
manufacturer’s instructions.
B. Wall, deck, and/or shower door
is improperly sealed.
B. Apply silicone sealant at the seams
between the bath and the wall,
deck, or door.
C. Cracked piping or air channels. C. Refer to the manufacturer.
13. Bath does not purge
automatically.
A. Level sensor wires are
disconnected.
A. Connect the level sensor wires.
Chromatherapy (if equipped)
Symptoms Probable Causes Recommended Action
14. Chromatherapy lights do
not work.
A. Loose, disconnected or damaged
wiring/connections.
A. Check wiring for proper
connections. Replace wiring if
necessary.
B. Control does not work. B. Replace control.
15. Chromatherapy does not
cycle.
A. Chromatherapy harness
assembly does not work.
A. Replace the chromatherapy harness
assembly.
1199249-2-B 20 Kohler Co.