Specification Sheet
1" (25 mm)
Notes
Required Electrical Service
Measure your actual product for rough-in details.
One circuit required, protected with Class A Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
Install this product according to the installation
instructions.
120 V, 15 A, 60 HzBlower, Heated
Surface:
The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.
Technical Information
All product dimensions are nominal.
Provide one grounded electrical outlet within 24"
(610 mm) of each component.
Drop-inInstallation:
EndDrain location:
Remote blower installation kit K-1446 is available
for relocating the blower. Provide access for
servicing the blower.
42" x 20" (1067 mm x 508 mm)Basin area, bottom:
51" x 24" (1295 mm x 610 mm)Basin area, top:
90 lbs (40.8 kg)Weight:
Do not relocate or alter the PVC tee or coiled
flexible tubing connected to the blower. Follow
the blower relocation instructions exactly.
47 lbs/ft² (229.5 kg/m²)Minimum floor load:
14" (356 mm)Water depth:
60 gal (227.1 L)Water capacity:
Drop-in, 58" x 30" (1473 mm x 762 mm)Cutout:
Blower: 120 V, 10 A, 60 Hz, 300 W
Heated Surface: 120 V, 0.5 A, 60 Hz, 65
W
Electrical component
rating:
2-1/2" (64 mm)Minimum flat for door:
USA/Canada: 1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
3-7-2017 05:34
Devonshire
®
5' BubbleMassage
™
Bath
K-1357-GW