4. Make the Electrical Connections
DANGER: Risk of electric shock. Connect the junction box, blower motor, and bubble heater to
properly grounded, grounding-type receptacles protected by a Ground-Fault Circuit-Interrupter
(GFCI)*. Do not remove the grounding pins from the plugs. Do not use grounding adapters.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
NOTICE: This product requires remote blower installation. Refer to the instructions included with the
remote blower kit.
NOTICE: The blower, junction box, and bubble heater are equipped with cords and plugs. A qualified
electrician must install three GFCI*-protected, 120 V, 15 A, grounded outlets. The blower and junction box
can be on the same dedicated circuit (circuit #1), but no other load should be on this circuit. The bubble
heater must be on its own dedicated circuit (circuit #2). No other load should be on this circuit.
For Wireless Music Kit: The kit requires installation of an electrical outlet within close proximity to
the amplifier location. Refer to the music kit installation instructions.
Install 3 electrical outlets within reach of the 24″ (610 mm) power cords.
Plug the blower cord into the outlet in circuit #1.
Plug the junction box cord into the other outlet in circuit #1.
*Outside North America, this device may be known as a Residual Current Device (RCD).