Installation Guide

4. Install the Electrical Outlet USA and Mexico
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock. Connect the blower motor to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the grounding pin from the plug. Do not use a grounding
adapter.
NOTICE: The blower motor is equipped with a cord and plug. A qualified electrician must install a GFCI-
or RCD-protected, 120 V, 15 A, grounded outlet for the blower. No other load should be on this circuit.
Install an electrical outlet inside the shroud, at least 1-1/2 (38 mm) above the subfloor, and within
reach of the 24 (610 mm) power cord.
NOTICE: For -G2M Music Models: Refer to the installation instructions included with the amplifier for
wiring and installation details. Position the amplifier anywhere within the shroud or in a remote location.
If installed within the shroud, the amplifier will need to remain plugged into the electrical outlet at all
times.
Install a GFCI-protected
120 V, 15 A grounded outlet.
Bond in accordance
with applicable codes.
Air Intake
24" (610 mm) Max. Distance
Between Blower and Outlet
1237791-2-D 8 Kohler Co.