Specification

Technical Information
Fixture:
Water supply pressure 20 psi (1.38 bar) - 80 psi
(5.52 bar)
Electrical rating 120 VAC / 60 Hz / 1260 W
Power cord length 46 (1.17 m)
A dedicated circuit protected with a Class A Ground-Fault
Circuit-Interrupter (GFCI) or Earth-Leakage Circuit
Breaker (ELCB) is required.
Installation Notes
Install this product according to the installation guide.
14-9/16"
(37 cm)
4-7/8"
(12.4 cm)
2"
(5.1 cm)
2"
(5.1 cm)
7/8" (2.2 cm)
11-1/16" (28.1 cm)
16-3/8" (41.6 cm)
16-3/8" (41.6 cm)
20-1/4" (51.4 cm)
7-13/16"
(19.8 cm)
2" (5.1 cm)
6" (15.2 cm) Min
ELECTRICAL SERVICE DETAIL
REMOTE
The receptacle should be located at least 6" (15.2 cm) above
the floor line, and within a 32" (81.3 cm) radius measured
2" (5.1 cm) to the right of the toilet ledge, as shown.
32" (81.3 cm) R.
Product Diagram
C
3
TM - 200
C
3
TM - 200 TOILET SEAT WITH BIDET FUNCTIONALITY
Page2of2
1054180-4-