Installation Guide

Determine the System Layout (cont.)
Ensure this steam generator is installed level.
Allow for access to the steam generator after installation.
Select the steam generator size based upon the steam room volumes identified below.
NOTE: For every additional foot of ceiling height above 8’ (2.4 m) choose the next largest steam
generator.
Steam Generator Steam Room Volume - Cubic Feet (Cubic Meters)
5 kW 84 (2.4)
7 kW 112 (3.2)
9 kW 240 (6.8)
11 kW 317 (9.0)
18 kW 550 (15.6)
22 kW 634 (18.0)
Kohler Co. 7 1230487-2-C