Installation Guide

Roughing-In
NOTE: Use the dimensions in the diagram above for reference when determining the placement and
clearance for the steam generator.
NOTE: Unions are supplied for the steam, drain, and water inlet connections.
1/2" NPT
Steam Outlet
3/8" NPT
Water Inlet
14"
(356 mm)
3/4" NPT
Pressure Relief
Field Wiring
Service Box
Green LED
Diagnostic Light
Control
Cable Input
Allow for a minimum of 12" (305 mm) of
space around all sides of the steam generator.
Allow for the drain/spill pan.
KOHLER
® drain pan (shown) sold separately.
Minimum required access panel is
24" (610 mm) L x 15" (381 mm) H.
11-11/16"
(297 mm)
3-1/2"
(89 mm)
17-15/16" (456 mm)
4-13/16"
(122 mm)
4-3/8"
(111 mm)
1-7/8"
(48 mm)
19-3/8" (492 mm)
3-5/8"
(92 mm)
2-5/8"
(67 mm)
3-3/4"
(95 mm)
6-9/16"
(167 mm)
9-9/16"
(243 mm)
1-3/4"
(44 mm)
2-5/8"
(67 mm)
13-9/16"
(344 mm)
2-1/8"
(54 mm)
3/4" NPT
Drain Pan Outlet
3/4"
(19 mm)
2"
(51 mm)
8-1/4"
(210 mm)
Kohler Co. 5 1230488-2-B