Installation Guide

Before You Begin
WARNING: Risk of personal injury. A user interface must
be located within the steam enclosure to allow temperature
regulation and control of the steam flow.
NOTICE: Do not locate the user interface on the same wall as the
steam head(s).
NOTICE: The temperature sensor must be located on the wall
opposite the steam head(s).
If possible install the steam generator(s) and K-99695 system
controller before beginning this installation.
Locate the steam head 6 (152 mm) above the floor and 4-1/2
(114 mm) from the inside of the threshold.
If two steam heads are used, there must be at least 12-1/2 (318
mm) between the center of each hole. The steam heads do not
need to be located in the same area.
Locate the steam head(s) as far away as possible from any shower
seating area.
Locate the temperature sensor on the wall 5 (127 mm) down
from the ceiling.
Make sure there is adequate clearance between the steam lines
and any surrounding surfaces, or apply appropriate insulation to
the steam lines.
Temperature
Sensor
Steam
Head
Shower
6"
(152 mm)
Bath
Steam
Head
5"
(127 mm)
6"
(152 mm)
5"
(127 mm)
4-1/2"
(114 mm)
Min
Threshold
6"
(152 mm)
From Floor
Temperature
Sensor
1235393-2-C 4 Kohler Co.