Specification

6-3/4"
Notes
Required Electrical Service
Measure your actual product for roughing-in
details.
One dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD).
Install this product according to the installation
guide.
120 V, 15 A, 60 Hz, 300 WBlower:
Hot water supply should be 70% of capacity or
greater. Installations will vary.
Technical Information
All product dimensions are nominal.
Locate a GFCI-protected 120 V, 15 A grounded
electrical outlet within 24" (610 mm) of the blower
motor.
FreestandingInstallation:
ReversibleDrain location:
43" x 25-5/8" (1093 mm x 651 mm)Basin area, bottom:
55-9/16" x 28-3/8" (1411 mm x 720 mm)Basin area, top:
94.5 lbs (42.9 kg)Weight:
45.4 lbs/ft² (221.7 kg/m²)Minimum floor load:
16-5/16" (415 mm)Water depth:
72.017 gal (272.6 L)Water capacity:
Blower: 120 V, 10 A, 60 Hz, 300 WElectrical rating:
VariablePump speed:
USA/Canada: 1-800-4KOHLER (1-800-456-4537)
www.kohler.com
2-18-2015 03:17
Underscore
®
5' BubbleMassage
Bath
K-5702-G