Installation & Assembly

4. Make the Electrical Connections
DANGER: Risk of electric shock. Connect the blower motor, and bubble heater to properly
grounded, grounding-type receptacles protected by a Ground-Fault Circuit-Interrupter (GFCI)*. Do
not remove the grounding pins from the plugs. Do not use grounding adapters.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing
the following procedures.
NOTICE: This product requires remote blower installation. Refer to the instructions included with the
remote blower kit.
NOTICE: The blower and bubble heater are equipped with cords and plugs. A qualified electrician must
install two GFCI*-protected, 120 V, 15 A, grounded outlets. No other load should be on this circuit.
For Wireless Music Kit: The kit requires installation of an electrical outlet within close proximity to
the amplifier location. Refer to the music kit installation instructions.
Install 2 electrical outlets within reach of the 24 (610 mm) power cords.
Plug the blower cord into one of these outlets.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Install a GFCI-protected
120 V, 15 A grounded outlet.
Bond in accordance
with applicable codes.
Air Intake
24" (610 mm) Max. Distance
Between Blower and Outlet
1385103-2-A 8 Kohler Co.