Installation Guide

9. Install the Amplifier
WARNING: Risk of electric shock. Connect the control amplifier to a properly grounded,
grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual
Current Device (RCD). Do not remove the grounding pin from the plug or use a grounding adapter.
IMPORTANT! Keep insulating materials away from the control amplifier. Provide an unobstructed air
space around the control amplifier to permit cooling.
NOTE: Do not remove the mounting brackets from the control amplifier.
Position the amplifier flush or recessed from the front of the studs.
Using the wood screws provided, secure the control amplifier to the framing. Use the anchors
provided if securing to a wall material other than wood.
NOTE: To make wiring connections more accessible, temporarily secure the control amplifier with one
screw on each side to allow the amplifier to tilt forward. Once wiring connections are made, secure the
control amplifier with the remaining screws.
Remove the cover from the control amplifier by removing the four screws. Retain for reinstallation.
NOTE: The transducer terminals and wires are numbered to identify the correct connections. When
required, the control amplifier can be removed to aid in the wire connection process.
Securely attach the transducer wires to the transducer terminals. The white with black wires are the
positive (+) leads.
If equipped, connect the chromatherapy connector to the chromatherapy terminal.
Connect the user interface connector to the user interface terminal.
If used, connect the optional auxiliary-in RCA connectors to the auxiliary-in terminals.
Reinstall the cover to the control amplifier with the four screws.
Plug the control amplifier into the electrical outlet.
Auxiliary In
Chromatherapy
(Some Models)
User Interface
Screws
Alternate Holes
Transducer Wiring
Screws
Control
Amplifier
Cover
Grounded Outlet
1237789-2-C 12 Kohler Co.