Installation Guide

Troubleshooting (cont.)
(Optional) Chromatherapy Troubleshooting Table
Symptom Probable Cause Recommended Action
G. Chromatherapy control does not
work.
G. Replace the Chromatherapy
control.
2. Chromatherapy lights do
not cycle through all
colors.
A. Control amplifier must be reset. A. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
B. Chromatherapy or user interface
cable connections are loose or
damaged.
B. Inspect the cables for loose
connections or damage. Secure or
replace cables as needed.
C. Control amplifier does not
work.
C. If the red LED on the control
amplifier does not blink following
restart, check the control amplifier
and replace as needed.
D. User interface does not work. D. Cycle through the Chromatherapy
light functions. If the lights do not
cycle through all colors and the
blue icon on the user interface is
not lit, replace the user interface.
E. If none of the recommended
actions correct the problem,
contact Kohler Co.
E. Contact the Customer Care Center
using the contact information on
the back cover.
Kohler Co. 17 1237789-2-C