Installation Guide

8. Install the Door Panel
NOTE: The door may require adjustment; do not make final adjustments until the header and handle are
installed.
CAUTION: Risk of injury or product damage. Unframed tempered glass should not contact hard
surfaces or it may shatter. Do not touch the edge of the tempered glass panel with tools or any hard
objects. Do not set the unframed tempered glass directly on the floor.
Slide the hinge jamb into the other wall jamb. Each slot in the hinge jamb will slide over the screw
body and fit between the clamp and wall jamb.
Tighten the four flathead screws, using the 3/32 hex wrench, until snug.
Glass
Glass
Strike Seal
Wall Jamb
Hinge Jamb
Wall Jamb
Adjust the top edge of
the door glass to be
even with the top edge
of the strike seal.
Wall Jamb
Hinge Jamb
Wall Jamb
Top View
Latch
Flathead Screw
Adjustment
Clamp
Strike Seal
3/16"
(5 mm)
Strike Jamb
3/16"
(5 mm)
1036565-2-D 12 Kohler Co.