Installation Guide

Tin SnipsRubber Mallet
5/16" Masonry
Bit for Tile
3/32", 5/32"
100% Silicone
Sealant
Masking Tape
32 Teeth Per Inch
Blade
5/16"
Threshold
1270824-01**
Screw
1048208-D
Screw
1048208-C
1077762
Anchor
1222601-01**
Wall Jamb
Fixed Panel
Seal
1223352-01
Bulb Seal
1070676-03**
Screw
1048208-AB
Threshold Seal
Strike Jamb
Seal
1070675-03**
Strike Jamb
1223081-01**
Spacer
1224612**
U-Channel
1224903-01**
End Cap
1223355-01
8-18 X 1-1/2"
8-18 X 5/8"
8-18 X 7/8"
Fixed Panel
1222162-01**
Slide Kit
1226627**
Hinge Kit
1226628**
Wall Mount
Bracket Kit
1226599**
Door Panel
1222166-02**[31" (787 mm)]
1222162-01**
[36" (914 mm)]
1223351-01
Service Seal
(Not Included)
1013487-03
1223351-02
[28-5/16" (719 mm)]
[23-5/16" (592 mm)]
Handle
1035917**
1270824-02**
[31" (787 mm)]
[37" (940 mm)]
Top View
Showerhead
Strike Side
Handle
Pivot Side
Right Pivot
x2
Gasket
#1222950
Hinge Bracket
Back Plate
Label
5/32"
1/4-20 X 1/2"
x2
1/4-20 X 1/2"
5/32"
Seal
Label
Wall Mount
Bracket
Wall
Mount
Plate
Gasket
#1222949
U-Channel
Pivot Side
Insert
Side View
Outside of
Shower
Top View
Showerhead
Strike Side
Pivot Side
Handle
Left Pivot
x2
Door Panel
Outside of
Shower
Bushing
Label
Back Plate
Pin
5/32"
1/4-20 X 3/4"
x2x2
Slider
Assembly
Gaskets
"A" Mark
Threshold
Tape
Measure
A
A
Cut here.
1/16" (2 mm)
Fixed
Panel
Y
X
YYY
X
X
X
Door Panel
YY
XX
Showerhead
Side
Threshold
Threshold
1/4"
(6 mm)
Threshold
U-Channel
Determine which side of the door will open. A right
side pivot is shown below.
The handle installs on the showerhead side and the
pivot installs on the side opposite the showerhead.
Left side pivot shown below. A left side pivot is shown
throughout the instructions.
The handle installs on the showerhead side and the
pivot installs opposite the showerhead.
Measure distance “A.” Mark and cut the threshold
1/16” (2 mm) or the width of a saw blade less than “A.”
Dry fit the threshold.
If needed, file the ends to match the corners and remove
burrs.
Position the threshold 1/4” (6 mm) from the front of the
ledge. Mark the location.
Remove and apply silicone sealant in the channel on the
bottom of the threshold.
Install the threshold on the ledge, tight against the wall
with the showerhead.
Confirm the black insert is in place in the U-channel.
If needed file the end of the U-channel to align with the
corner wall contour.
Install the U-channel on the pivot side of the threshold.
Position gaskets #1222949, on the wall mount bracket
and wall mount plate. Confirm the gaskets are correctly
oriented.
On the side opposite the Clean Coat label, position the
wall mount bracket. Install the wall mount plate to the
fixed panel and secure. Install the clear plastic seal,
leaving a 1/2” (13 mm) gap at the bottom.
Position gaskets #1222950 on the back plate and hinge
bracket.
Confirm the gaskets are correctly oriented.
On the fixed panel, position the back plate on the wall
mount bracket side and hinge bracket on the CleanCoat
label side and loosely secure.
Position the gaskets on the back plate and slider
assembly.
Position the slider assembly on the CleanCoat label side
of the door panel, pin oriented downward. Attach the
back plate with a 1/4-20 x 3/4” fastener.
Tighten with a 5/32” hex wrench. Confirm the bushings
are installed in the pivot hinge.
Reinstall the bushings if needed.
IMPORTANT: It is critical that the brackets are
correctly located.
Measure the position of each bracket. Each dimension X
and each dimension Y should match.
Adjust the brackets as needed and securely tighten.
With a partner, position the fixed panel in the
U-channel.
Plumb the fixed panel using a level. Mark the locations
of the four wall mount bracket screw holes with a
nail or other sharp object, using the bracket holes as a
template. Remove the fixed panel and place it on a piece
of cardboard or other protective material.
• Walls must be within 3/8” (10 mm) of plumb. This unit will
not function properly if the walls are more than 3/8” (10 mm)
out-of-plumb.
• Confirm the door and glass panels will not contact any objects
when opened.
• Cover the drain with tape to avoid loss of small parts.
• Follow the silicone sealant manufacturer’s instructions for
application and curing time.
• Perform this installation with two people.
Pivot Shower Doors
1
1220848-2-D
Installation and Care Guide
*Call Customer Care Center to order replacement parts.
**Finish/color code must be specifi ed when ordering.
Retain this document for future servicing.
Record model number from box for reference.
Model Number:______________
Required Tools Parts Identifi cation
Pivot Shower Door
K-709032, K-709033, K-R709032, K-R709033
1 2
7
3
86
4
9
5
10
1220848-2-D
USA/Canada: 1-800-4KOHLER
México: 001-800-456-4537
kohler.com
WARNING: Risk of serious injury. Damage prior to
installation can result in glass shattering. Inspect the glass
and all parts for damage before installation.
WARNING: Risk of serious injury. Improper
installation can result in glass shattering. Follow all
installation instructions.
NOTICE: Do not touch the edges of the tempered glass
with tools or any other hard objects. Do not set the
unframed tempered glass directly on the floor or any
hard surface.
WARNING: Risk of serious injury. Do not cut tempered
glass. Tempered glass will shatter if cut.
WARNING: Risk of serious injury. Shower door and
side panels can shatter. Regularly inspect the glass and all
parts for damage, missing, or loose parts.
WARNING: Risk of serious injury. Always wear safety
glasses while cutting and drilling.
IMPORTANT! Leave this manual for the end user.
Read these instructions before installing or using this product.
Keep these instructions in a safe location for future reference.
These instructions can also be found at www.kohler.com

Summary of content (6 pages)