Installation Guide Continued

1. Faucet Installation
Prepare the Site - AC and Hybrid Models
NOTE: Before drilling the mounting hole, use the following
provisions for proper placement:
A 1-1/4 (32 mm) minimum to 1-1/2 (38 mm) maximum
diameter mounting hole is required.
A minimum distance of 1-3/4 (44 mm) is required between the
back of the spout and the wall to allow access to the screw.
A 1-1/8 (29 mm) maximum distance is required between the
sink bowl edge and the base of the spout.
AAA Battery Operated Models Only
NOTE: When K-13460, K-13461, K-13466 or K-13467 are installed to
drop-in sinks (sinks with the rim above the deck), the maximum
height of the edge of the basin lip is 3/4 (19 mm) and the
maximum distance from the edge of the sink to the front edge of the
faucet is 1/2 (13 mm).
NOTE: When K-13472 or K-13473 are installed to drop-in sinks, the
maximum height of the edge of the basin lip is 1-1/4 (32 mm).
NOTE: Before drilling the mounting hole, use the following
provisions for proper placement:
A 1-1/4 (32 mm) minimum to 1-1/2 (38 mm) maximum
diameter mounting hole is required.
Without Escutcheon
Spout
Stud
O-ring
Rubber Washer
Bracket
Nut
Supply Hoses
Kohler Co. 3 1244026-2-A