Installation Guide

5. Mount the Blower Motor - Remote Site
NOTE: The blower motor must be mounted horizontally 1-1/2 (38 mm) above the floor. Do not mount
the blower motor with the discharge pointing up.
NOTE: Refer to the Prepare the Blower - Remote Site section for other requirements for the blower
motor relocation.
At the new blower motor location, install a 1-1/2 (38 mm) high block (not supplied) to support the
blower motor.
Install and support PVC or other 1-1/2 rigid piping (not supplied) between the blower motor
location and the air harness.
Connect the new piping to the existing air harness without modifying the air harness. Align the new
pipe and secure the connection with PVC cement. Allow the PVC cement to cure according to the
manufacturer’s instructions.
Position the motor on the support block.
Fasten the blower motor to the new support block with the mounting screws previously retained.
Blower Motor Mounting Screws
1-1/2" (38 mm) Min
Kohler Co. 9 1199249-2-C