Specification Sheet

VIGORA
1.25>132
PUMP/CONTROL ACCESS
3”
2” O.D.
3-1/2”
11/16”
21”
2”
9”
72”
3”
23-1/2”
24-1/2”
42”
REQUIRED ELECTRICAL SERVICE
Dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V, 20 A, 60 Hz
PRODUCT INFORMATION
Fixture*: basin area top area weight
Bathing well 47” x 27” 64” x 29” 130 lbs.
water depth capacity
To overflow 19-1/2” 125 gal.
* Approximate measurements for comparison only.
Pump: HP V Hz A
1-speed 2 120 60 18.5
Included Components:
Cutout template 114323-7
INSTALLATION NOTES
NOTICE: Unless otherwise specified, floor support under whirl-
pool must provide for a minimum of 80 lbs./square foot loading.
If installing a rim-mount faucet, make sure there is no inter-
ference with drain overflow and circulating system before
drilling any holes. Consult local and national codes for mini-
mum air gap requirements if installing a spout on the faucet
deck.
Each pump is supplied with grounding-type plug-in cord. Locate
the outlet behind the whirlpool, and within 24” of the pump.
Roughing-In Notes
No change in measurements if connected with drain
illustrated.
Minimum access panel:
Pump/control 36” W x 20” H required
K-1339 Vigora Bath Whirlpool
Page 2 of 2
87301-4-BA
PRODUCT DIAGRAM