Owner's Manual

Shower Configuration A Plumbing Layout 2
IMPORTANT! For proper shower system setup and performance, especially regarding massage and spa
function, refer to the Shower Configurations Overview section for important information.
Valves/Outlets Used
Six-port valve (zone 1) = 6
Six-port valve (zone 2) = 4
Flow Rates
NOTE: Water flow rates are calculated below based on 10 used outlet ports with equal flow rates. If
additional valve outlets are being used, or your fittings have varying flow, calculate the total flow rate
accordingly.
Total, with 2.2 gal/min (8.3 l/min) per outlet = 22 gal/min (83.3 l/min)
Maximum total, with 2.5 gal/min (9.5 l/min) per outlet = 25 gal/min (94.6 l/min)
Massage Options
Single
Wave
Spa Compatibility
Relax
Focus - calm energy
Breathe
6
123456
6-Port Valve
(Zone 2)
3
5
3
4
1
5
2
4
1
2
123 456
6-Port Valve
(Zone 1)
Kohler Co. 11 1241234-5-A