Owner's Manual

Web Settings Valve
Web page path: Settings > Valve 1 (or Valve 2)
IMPORTANT! For proper function for a multiple valve system, valve 1 (zone 1) must be connected to the
system controller before valve 2 (zone 2). Confirm that valve 1 appears on the Web page before connecting
the second valve to the controller.
Valve Configuration Custom Options
For preprogrammed configurations, refer to the Configurations sections.
Function: sets the outlet icons of your custom configuration to match your shower installation.
IMPORTANT! The fitting shown in the outlet window on the Web page should be the fitting that is
physically plumbed to that valve outlet.
Click the icon window to scroll through the list of available water outlet options for your shower
configuration (see Water Outlet Options section).
Select Default Outlet
Function: sets the water outlet that will turn on if the user makes no shower selections before
touching the [start] icon on the interface.
Determine the primary outlet by clicking the radial button next to Default. Only one default outlet
can be selected per system.
Add/Remove Outlets from Massage Cycling Pattern
Function: sets the water outlets that will cycle when the massage functions are activated.
Add or remove outlets by clicking the radial button next to Massage.
Settings Service
(example: 1,3,2,4,6,5)
Valve 1
UsersSystem
Outlet 1
Default
Massage
Auto Purge
Outlet 2
Default
Massage
Auto Purge
Outlet 3
Default
Massage
Auto Purge
Temperature
Outlet 4
Default
Massage
Auto Purge
Outlet 5
Default
Massage
Auto Purge
Outlet 6
Default
Massage
Auto Purge
MusicInterfaceValve 2 Lighting Steam
About
Default Temperature
Max Temperature
100
113
5 Minutes
Cold Water
Auto Purge
7 Seconds
Custom Massage Order
Custom Massage Order
Kohler Co. 23 1241234-5-A