Installation Guide

Panel Adjustment and Maintenance
NOTICE: The panels may require adjustment to ensure that they touch the top and bottom bumpers in
the proper closed position. The inside panel should close on the showerhead side, and the outside panel
should close on the opposite side.
To adjust the panels, loosen the roller bolt with the provided wrench. Do not over-loosen!
Adjust the alignment of each end of the panel by turning the roller with the provided wrench.
Continue until the door operates smoothly, aligns evenly with the shower walls, and the door
panels make contact with the top and bottom bumpers at the same time.
When complete, securely tighten all four roller bolts at least 3/4 turn past hand-tight.
Maintenance
Check roller tightness annually.
Retain the provided wrench for future adjustment or re-tightening.
Tighten Bolt
Adjust Roller CamLoosen Bolt
1380408-2-B 28 Kohler Co.