Specifications

Required Accessories
K-304-* Rite-Temp
®
pressure-balancing valve OR NA
K-2971-KS HiFlow Rite-Temp valve with stops OR NA
K-11748-* Rite-Temp valve with push-button diverter NA
* For a complete listing of all the Rite-Temp valves, refer to the individual valve Specification Sheet or Roughing-In Sheet.
Optional Accessories
1204798 Deep roughing-in kit for Rite-Temp valve CP Other ____
Installation Notes
Install the product according to the installation guide.
Install the Rite-Temp valve according to the installation guide.
NOTICE: For K-2971-KS valve: 1-5/8 (41 mm) screws
(included) must be used. 2-3/8 (60 mm) screws will damage
the valve.
Avoid cross-flow conditions. Do not install a shut-off device on
any valve outlet.
Cap the shower outlet if the deck-mounted spout, diverter, or
handshower is connected to the spout outlet (applies only to
K-304 valve).
Install a 7 (178 mm) to 18 (457 mm) straight pipe or straight
tube with single elbow between the valve and the wall-mount
spout.
Deep Rough-in Kit 1204798 is required if Rite-Temp valve
inlets are more than 3-1/2 (89 mm) from the finished wall.
The kit will accommodate a valve with inlets up to 4-1/2 (114
mm) from the finished wall.
Ø 6-9/16"
(167 mm)
Centerline
of Valve
Inlet
2-3/4" (70 mm) Thin Wall
3-1/2" (89 mm) Thick Wall
If over 3-1/2" (89 mm) and up to
4-1/2" (114 mm), use Deep
Roughing-in kit.
4-1/2"
(114 mm)
3-5/16"
(84 mm)
K-T72767-9M
Ø 6-9/16"
(167 mm)
Ø 6-9/16"
(167 mm)
Centerline
of Valve
Inlet
2-3/4" (70 mm) Thin Wall
3-1/2" (89 mm) Thick Wall
If over 3-1/2" (89 mm) and up to
4-1/2" (114 mm), use Deep
Roughing-in kit.
5"
(127 mm)
3-5/16"
(84 mm)
K-T72767-4
Centerline
of Valve
Inlet
2-3/4" (70 mm) Thin Wall
3-1/2" (89 mm) Thick Wall
If over 3-1/2" (89 mm) and up to
4-1/2" (114 mm), use Deep
Roughing-in kit.
5-1/4"
(133 mm)
K-T72767-3M
1-1/2"
(38 mm)
Product Diagram
ARTIFACTSTM RITE-TEMP
®
ARTIFACTSTM RITE-TEMP
®
VALVE TRIM
Page2of2
1204794-4-
A