Product Card
KD200
ALTERNATOR CHARACTERISTICS
GENERAL DATA
Alternator type KH01100T
Number of Phase
Three phase
Power factor (Cos Phi)
0.8
Altitude (m)
0 to 1000
Overspeed (rpm)
2250
Number of pole
4
Capacity for maintaining short circuit at
3 ln for 10 s
No
Insulation class
H
T° class (H/125°), continuous 40°C
H / 125°K
T° class, standby 27°C
H / 163°K
AVR Regulation
Yes
Total Harmonic Distortion in no-load
DHT (%)
<2.5
Total Harmonic Distortion, on load DHT
(%)
<2.5
Wave form : NEMA=TIF
<50
Wave form : CEI=FHT
<2
Number of bearing
1
Coupling
Direct
0.5
500
Voltage regulation at established rating
(+/- %)
Recovery time (Delta U = 20%
transient) (ms)
Protection class
IP 23
Technology
Without collar or
brush
OTHER DATA
Continuous Nominal Rating 40°C (kVA)
180
Standby Rating 27°C (kVA)
200
Efficiencies 100% of load (%)
91.9
Air flow (m3/s)
0.48
Short circuit ratio (Kcc)
0.345
Direct axis synchro reactance unsaturated (Xd) (%)
366
Quadrature-axis synchro reactance unsaturated (Xq)
(%)
Open circuit time constant (T'do) (ms)
2276
Direct axis transient reactance saturated (X'd) (%) 16.1
100
12.8
10
16.8
Short circuit transient time constant (T'd) (ms)
Direct axis subtransient reactance saturated (X''d) (%)
Subtransient time constant (T"d) (ms)
Quadrature-axis subtransient reactance saturated
(X"q) (%)
Subtransient time constant (T"q) (ms)
10
Zero sequence reactance unsaturated (Xo) (%) 0.6
Negative sequence reactance saturated (X2) (%) 14.88
Armature time constant (Ta) (ms) 15
No load excitation current (io) (A) 0.7
Full load excitation current (ic) (A) 2.99
40.9
407.6
Full load excitation voltage (uc) (V)
Engine start (Delta U = 20% perm. or 50% trans.)
(kVA)
Transient dip (4/4 load) - PF : 0,8 AR (%)
14
No load losses (W)
3035.69
Heat rejection (W)
12607.78
DIMENSIONS
M226
3508
1200
1830
2306
340
76
Dimensions soundproofed version
Commercial reference of the enclosure
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
95
Dimensions DW compact version
Commercial reference of the enclosure
-
3560
1180
1822
2119
868
-
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
-
This document is not contractual - Kohler Co. reserves the right to modify any of the characteristics without notice,
in a constant effort to improve the quality of its products.
GBD5-03010 (KD200) 03/17
187
Unbalanced load acceptance ratio (%)
100
65
-
M226 DW
3560
1200
2182
2699
868
76
Dimensions DW soundproofed version
Commercial reference of the enclosure
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
95
Dimensions DW 48h soundproofed version
M226 DW48
3560
1200
2364
2964
1630
76
Commercial reference of the enclosure
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A)
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A)
95
65
65