User Manual
6
THREE-PHASE GENERATOR SETS
Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications
kVA kW Engine Alternator Unhoused Version(5)
Generator
Set Model(1)
Prime
Power(3)
Standby
Power(4)
Fuel
Consumption
3/4 L/h
Generator
Set
Model(2)
Prime
Power(3)
Standby
Power(4)
Fuel
Consumption
3/4 L/h
Engine
Type
Cyl. Bore,
mm
Stroke,
mm
Cyl,
L
Type Dimensions,
L x W x H, m
Weight,
kg(6)
Tank
Capacity,
L
KV220C2
200 220 31.7
KV200U
182 200 35.2 TAD733GE 6L 108 130 7.15 LSA462M5 2.37 x 1.11 x
1.54
1850 340
KV275C2
250 275 42.6 — — — — TAD734GE 6L 108 130 7.15 LSA462L6 2.9 x 1.3
x 1.6
2200 390
————
KV250U
227 250 45.7 TAD734GE 6L 108 130 7.15 LSA462L9 2.9 x 1.3
x 1.6
2260 390
KV350C2
300 330 50.6
KV300U
273 300 52.8 TAD941GE 6L 120 138 9.4 LSA462VL12 3.16 x 1.34 x
1.76
2850 470
KV375C2
341 375 50.6 — — — — TAD941GE 6L 120 138 9.4 LSA472VS2 3.16 x 1.34 x
1.76
2780 470
————
KV350U
319 350 58.5 TAD1241GE 6L 131 150 12.1 LSA472VS2 3.16 x 1.34 x
1.80
3206 470
KV410C2
375 413 55 — — — — TAD1241GE 6L 131 150 12.1 LSA472VS3 3.16 x 1.34 x
1.81
3190 470
KV440C2
400 440 59.5
KV400U
364 400 67.8 TAD1242GE 6L 131 150 12.1 LSA472VS3 3.16 x 1.34 x
1.81
3238 470
KV500C2
450 500 69.2
KV450U
409 450 78.4 TAD1640GE 6L 144 165 16.1 LSA472S5 3.47 x 1.50 x
2.04
3490 500
KV550C2
500 550 75.4
KV500UC2
455 500 88.8 TAD1641GE 6L 144 165 16.1 LSA472M7 3.47 x 1.50 x
2.04
3620 500
KV630C2
573 630 85.2 — — — — TAD1642GE 6L 144 165 16.1 LSA472L9 3.47 x 1.63 x
2.08
3780 610
————
KV550UC2
500 550 97.1 TAD1642GE 6L 144 165 16.1 LSA472M7 3.47 x 1.63 x
2.08
3650 610
KV700C2
636 700 94.5
KV600UC2
545 600 105.7 TWD1643GE 6L 144 165 16.1 LSA491S4 3.47 x 1.63 x
2.08
3890 610
(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.
(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.
(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528, a 10% overload capacity is available for a period of 1 hour every
12-hour period of operation, in accordance with IS03046-1.
(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.
(5) The dimensions and weights apply to an unhoused generator set without options.
(6) Dry weight, without fuel.
(7) Also available in the following voltages: 220-240 V.
N/A Not available
POWER PRODUCTS FROM
220 kVA TO 700 kVA/50 Hz
200 kW TO 600 kW/60 Hz
KV440C2 generator, shown with DEC4000 control KV630C2 generator, shown with DEC4000 control