Spec Sheet

G4-288 (KG100R) 9/21c
Lubrication
Lubricating System 60 Hz
Type Full Pressure
Oil pan capacity, L (qt.)
5.7 (6.0)
Oil pan capacity with filter and oil cooler,
L (qt.)
9.0 (9.5)
Oil filter: quantity, type
1, Cartridge
Kohler recommends the use of Kohler Genuine oil and filters.
Cooling
Radiator System 60 Hz
Ambient temperature, C (F)
45 (113)
Engine jacket water capacity, L (gal.) 7.3 (1.93)
Radiator system capacity, including
engine, L (gal.)
28.4 (7.5)
Engine jacket water flow, Lpm (gpm) 126 (33.3)
Heat rejected to cooling water at rated
kW, dry exhaust, kW (Btu/min.)
73.9 (4207)
Heat rejected to charge air cooler at
rated kW, dry exhaust, kW (Btu/min.)
18 (1025)
Water pump type Centrifugal
Fan diameter, including blades, mm (in.) 711 (28)
Fan, kWm (HP) 12.0 (16.1)
Max. restriction of cooling air, intake and
discharge side of radiator, kPa (in. H
2
O)
0.12 (0.5)
Operation Requirements
Air Requirements 60 Hz
Radiator-cooled cooling air,
m
3
/min. (scfm)
290 (10,241)
Combustion air, m
3
/min. (cfm) 6.9 (244)
Heat rejected to ambient air:
Engine, kW (Btu/min.) 30 (1708)
Alternator, kW (Btu/min.) 8 (455)
Air density = 1.20 kg/m
3
(0.075 lbm/ft
3
)
Fuel Consumption
60 Hz
Natural Gas, m
3
/hr. (cfh) at % load Standby Ratings
100% 41.7 (1473)
75% 34.7 (1224)
50% 26.8 (946)
25% 17.7 (625)
0% 8.3 (292)
LP Gas, m
3
/hr. (cfh) at % load Standby Ratings
100% 18.8 (664)
75% 15.1 (532)
50% 11.0 (388)
25% 6.1 (216)
0% 3.4 (121)
Nominal fuel rating: Natural gas, 37 MJ/m
3
(1000 Btu/ft.
3
)
LP vapor, 93 MJ/m
3
(2500 Btu/ft.
3
)
LP vapor conversion factors:
8.58 ft.
3
= 1 lb.
0.535 m
3
= 1 kg.
36.39 ft.
3
= 1 gal.
Controllers
APM402 Controller
Provides advanced control, system monitoring, and system diagnostics
for optimum performance and compatibility.
Digital display and menu control provide easy local data access
Measurements are selectable in metric or English units
Remote communication thru a PC via network or
serial configuration
Controller supports Modbus protocol
Integrated hybrid voltage regulator with ±0.5% regulation
Built-in alternator thermal overload protection
NFPA 110 Level 1 capability
Refer to G6-161 for additional controller features and accessories.
Sound Enclosure
Sound level (8 point logarithmic average) at 7 m (23 ft.) with full load:
69 dB(A).
Sound level compared to competitor ratings with no load: 68 dB(A).*
Sound attenuating enclosure uses acoustic insulation that meets
UL 94 HF1 flammability classification and repels moisture absorption.
Vertical air inlet and outlet discharge with 90 degree bends to redirect
air and reduce noise.
Internal-mounted critical silencer and flexible exhaust connector.
Skid-mounted, steel (standard) or aluminum (optional) construction
with hinged doors.
Fade-, scratch-, and corrosion-resistant Kohler Cashmere Power
Armor textured e-coat paint.
Lockable, flush-mounted door latches.
Certified to withstand 299 kph (186 mph) wind load rating (aluminum
enclosures only).
* Lowest of 8 points measured around the generator. Sound levels at
other points around generator may be higher depending on installation
parameters.