Battery - Safety Data Sheet

中能锂电科技泰州有限公
ZHONGNENG LITHIUM BATTERY TECHNOLOGY TAIZHOU
CO., LTD
江苏省泰州市中国医药城药城大道
799
NO.799,YAOCHENG AVENUE, CMC, TAIZHOU CITY,
JIANGSU
Tele: 0086-523-86226716
Fax: 0086-523-86226716
MATERIAL SAFETY DATA SHEET
Issue:
Charlie Chen Doc No: ZN-MSDS-18-001 Issue Date:2020.05.05
ZN confidential
There was no electrical shock risk for single cell, or battery module which
voltage was less than 50V DC (the safety voltage). But if the pack had the voltage
was bigger than 50V DC, the electrical shock shall be protected.
During the shipment or testing process for LIB Pack or Module, there was danger
factors like drop, crush, broken, metal short circuit, liquid immersion, the factors
would lead the risk like electrical shock, catch fire. If pack was in well sealed box,
there was gas exploding risk; if the pack was in big room or fans, there was not
explode risk. The released liquid was the environment population risk.
5.2 Material prepare & people training
1 Water based sprayer fire extinguish: 1 set of 9L or 2 sets of 6L water spray
fire extinguishers per each 500KWh LIB pack or Modules. Or you could use
portable electrical water sprayer or hang type water spray fire extinguisher
(photo 1). The water-based spray fire extinguisher could be used for fire type
ABCE = solid (A), flash point >60℃ liquid (B), gas (C), <36Kv electrical
(E) fire. It was recommended to prepare water-based sprayers in the trucks.
2Water protection sets: raincoat, galoshes, and rubber gloves. Plastic rollers.
Rags.
3 PPE: breathing mask, safety glass, face mask, gloves for high temperature.
4 Smoke escape: fans in wall one per 20m or portable fans in rooms. Keep gas
exchange hole in trucks.
5 Gases explode tools: open condition for devices & rooms. Some devices like
high or low temperature ovens must be sealed; there was one copper film
with the diameter 200mm & thickness 8um as the safety vent. The wall should
have one fan per 20m, ≥5000m
3
per hour for flow rate.
6 Neutralized material: prepare 10kg Ca(OH)
2
powder per 500KWh LIB pack or
modules, it was
used for neutralized for release electrolyte. Because electrolyte met with