GENERATOR SET CONTROLS
DEC4000 
SPECIFICATIONS
(1) Control and automatic operation present, but require the 
 “Prewiring for auto startup” option and possibly the 
 configuration of a parameter on the DEC4000.
(2) The choice of alarm or fault is made by programming on 
 the keyboard.
(3) Differential protection is ensured by an exterior module.
(4) DS detection is provided using the source changeover 
 switch as a base. If the source changeover switch is not 
 chosen, the DS module can be fitted in the control unit.
(5) To find out more detailed contents, please contact your 
 KOHLER distributor.
(6) Standard NFE37312.
Powers (active, reactive) 
Composite voltages 
Single voltages 
Phase current 
Neutral current
Frequency 
All states of the generator set,
all starting phases 
Analog indicator 
Battery ammeter 
Engine speed indicator 
Battery voltage indicator 
Working hours counter
Speed/voltage trimming 
Power on 
Fuel solenoid valve control 
Starter control 
Preheating plug 
Water preheating 
Network switch (normal)
 (1)
Network switch (emergency)
 (1)
Oil pressure fault 
Coolant temperature fault 
Nonstarting fault 
Overspeed fault 
Genset ready to supply 
Charging alternator fault 
General alarm 
General fault 
Panel light 
STOP, MANU, AUTO, TEST modes 
Generating set switch closed (normal)
 (1)
Network switch closed (emergency)
 (1)
All alarm and/or fault messages 
Oil pressure fault 
Coolant temperature fault 
Emergency stop fault 
Short circuit or overload fault or alarm
(2)
Battery voltage min/max fault or alarm
(2)
Alternator voltage min/max fault or alarm
(2)
Alternator frequency min/max fault or alarm
(2)
Overspeed fault 
Presence of differential relay fault
 (3)
Differential relay triggered alarm or fault
 (2,3)
Automatic standby 
Automatic shutdown 
Four modes 
Engine stop for auto cooling 
Speed and voltage stabilization 
Preheating plug 
Registering retro information from the normal/emergency switch
 (1)
Switch from emergency to normal
 (1)
Switch from normal to emergency
 (1)
Manual closure of the generator set switch
 (1)
Manual opening of the generator set switch
 (1)
Starting on clock
 (1)
Remote starting order
 (1)
Three-phase mains detection
 (4)
Operation at -20ºC to +60ºC 
Humidity: 95% at 45ºC; 70% at 50ºC; 50% at 60ºC
Light test 
Fault reset 
Prewiring for auto startup 
Automatic pack
(charger+relay and engine preheater resistor) 
GES pack
(5)
 fitted on the genset
 (6)
NFPA 110 module (60 Hz) 
Adjustable differential protection (time and threshold)
 (2)
Sound alarm
Ability to connect up to five additional input/output 
modules (4 inputs/6 outputs)
Measurement
Engine Parameters
Controls
Indicator Lights/
Messages
Safety
Standard  Optional Standard  Optional
Automatic
Functions
Operational
Characteristics
Accessories