Product Card
KV650C2 
Engine type
TAD1642GE
Alternator type KH02880T
Performance class
G3
GENERAL CHARACTERISTICS 
Frequency (Hz)
Voltage (V)
Standard control panel
Optional control panel
Optional control panel
POWER
ESP
PRP
Voltage
kWe
kVA
kWe
kVA
Standby Amps
415/240 520 650 473 591 904
400/230 520 650 473 591 938
380/220 520 650 473 591 988
DIMENSIONS COMPACT VERSION
Length (mm)
3470
Width (mm)
1630
Height (mm)
2095
Dry weight (kg)
3780
Tank capacity (L)
610
DIMENSIONS SOUNDPROOFED VERSION
Commercial reference of the enclosure 
M230
5031
1690
2672
5300
610
80
Length (mm)
Width (mm)
Height (mm)
Dry weight (kg)
Tank capacity (L)
Acoustic pressure level @1m in dB(A) 
Sound power level guaranteed (Lwa)
Acoustic pressure level @7m in dB(A) 
100
This document is not contractual - Kohler Co. reserves
 the right to modify any of the characteristics without notice, in a constant effort to improve the quality of its products.  
GBD5-06007 (KV650C2) 03/17 
50
400/230 
DEC4000 
APM802
M80
DESCRIPTIVE
Kohler Co. Provides one-source responsibility for the 
generating system and accessories
The generator set and its components are prototype-  
tested, factory-built, and production-tested
 A one-year limited warranty covers all systems and 
 components 
POWER DEFINITION
PRP : Prime Power is available for an unlimited number of
 annual 
operating hours in variable load applications, in accordance with ISO 
8528-1. ESP : The standby power rating is applicable for supplying 
emergency power in variable load applications in accordance with ISO 
8528-1. Overload is not allowed
TERMS OF USE
According to the standard, the nominal power assigned by the genset is 
given for 25°C Air Intlet Temperature, of a barometric pressure of 100 
kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions 
in your installation, refer to the derating table.
ASSOCIATED UNCERTAINTY
For the generator sets used indoor, where the acoustic pressure levels 
depend on the installation conditions, it is not possible to specify the 
ambient noise level in the operating and maintenance instructions. 
You will also find in our operating and maintenance instructions a 
warning concerning the air noise dangers and the need to implement 
appropriate preventive measures.
 Electronic governor 
 Mechanically welded chassis with antivibration 
suspension 
 Main line circuit breaker 
 Radiator for core temperature of 48/50°C max with 
mechanical fan 
 Protective grille for fan and rotating parts (CE option) 
 9 dB(A) silencer supplied separately 
 Charger DC starting battery with electrolyte 
 24
 V charge alternator and starter 
 Delivered with oil and coolant -30°C 
 Manual for use and installation 
70
240 TRI 520 650 473 591 1564
230 TRI 520 650 473 591 1632
220 TRI 504 630 458 573 1653