TIP
9 “–” means below.
9 Application wattage indicates when each device is
used by itself.
9 The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
Generator rated output 2,500 VA
Frequency Power factor
AC
1.0 –2,380 W
0.8 –1,880 W
DC
120 W
(12 V/10 A)
9 The overload indicator light comes on when total
wattage exceeds the application range. (See page
19 for more details.)
1 Overload indicator light
760-021a
1
AE00812
Application range
When using the generator, make sure the total load is within rated output of a genera-
tor. Otherwise, generator damage may occur.
AC
DC
Power factor 1 0.8–0.95
0.4–0.75
(Efficiency 0.85)
PRO 2.8 i –2,500 W –2,000 W –850 W
Rated voltage
12 V
Rated current
10 A
7VU-28199-L1.indd 16 2014/01/09 10:16:01