Product Manual

KohlerPower.com33 590 04 36
AE00601
STORAGE
Long term storage of your generator will require some
preventive procedures to guard against deterioration.
AE00611
Drain the fuel
1. Turn the engine switch to “5” (STOP).
1 5” (STOP)
2. Remove the fuel tank cap and fuel tank filter.
Extract the fuel from the fuel tank into an
approved gasoline container using a commercially
available hand siphon. Then, install the fuel tank
filter and fuel tank cap.
WARN I N G
Fuel is highly flammable and poisonous. Check
“SAFETY INFORMATION” (See page 2) carefully.
NOTI CE
Immediately wipe off spilled fuel with a clean, dry,
soft cloth, since fuel may deteriorate painted sur-
faces or plastic parts.
3. Turn the engine switch to “7” (ON).
2 7” (ON)
4. Turn the fuel cock lever to ON.
3 ON
5. Start the engine and leave it run until it stops.
The engine stops in approximately 20 minutes
time by running out of fuel.
TIP
9 Do not connect with any electrical devices.
(unloaded operation)
9 Duration of the running engine depends on the
amount of the fuel left in the tank