Battery charging
NOTI CE
9 Do not connect a VRLA (Valve Regulated Lead
Acid) battery. To charge a VRLA battery, a spe-
cial (constant-voltage) battery charger is
required.
9 Do not use AC and DC power at the same time
or the generator may be damaged.
TIP
9 The generator DC rated voltage is 12 V.
9 Start the engine first, and then connect the gener-
ator to the battery for charging.
9 Before starting to charge the battery, make sure
that the DC protector is turned
“I” (RESET).
1. Start the engine.
3
4
1
2
763-005a
2. Press in the DC protector.
1 “I” (RESET)
2 3 (OFF)
3. Connect the red battery charger lead to the posi-
tive (+) battery terminal.
3 Red wire
4 Black wire
4. Connect the black battery charger lead to the
negative (–) battery terminal.
5. Turn the economy control switch “3 (OFF) to
start battery charging.