Repairing Minor Faults - MODYS Alarms and Faults
Pictograms
Color of
LED
Type of Fault Issue Possible Solution
Green Plug preheating
No issue: plug
preheating sequence
Red
Engine
temperature
Shutdown: abnormal
engine temperature
Allow generator to cool
down and check air
cleaner and vents on
enclosure.
Red
Battery or
charging
alternator
Problem with alternator
charge output or weak
battery
Contact a Kohler
portable dealer.
Red
Oil pressure or
low oil level
Shutdown: incorrect oil
pressure or low oil level
Allow generator to cool
down, top up and check
oil level.
Red Non-starting fault
3 consecutive
unsuccessful starting
attempts
Check that generator has
been started according to
recommendations in this
manual.
Red Overspeed
Shutdown: generator
rotation speed
excessive
Contact a Kohler portable
dealer.
Flashing
Red
Speed too low
Shutdown: insuf cient
generator rotation
speed
Contact a Kohler portable
dealer.
Troubleshooting
Do not attempt to service or replace major engine components, or any items that require special
timing or adjustment procedures. This work should be performed by a Kohler portable dealer.
Problem
Possible Cause
Engine Not
Starting/
Running
Abnormally
Engine
Stopped
No Electric
Current
Tripping
of Circuit
Breaker
Load connected to generating set
during start-up
Start and Stop control ON or OFF
Oil level too low ●●
Unsuitable fuel
Fuel level too low ●●
Fuel valve closed
Clogged fuel lter
Clogged air lter
Fuel supply blocked or leaking
Faulty starter battery
Blocked ventilation inlets
Circuit protectors not actuated
Faulty appliance supply cord
Faulty electrical sockets
Faulty alternator
Device connected or faulty cord
Overload
Battery Incorrectly Connected ●●
Faulty MODYS Fuses (R)