Installation Guide

3. Install the Handles
Remove the plaster guards.
Measure the distance from the top of the valve stem to the
finished surface.
For a valve stem height between 1-13/16 (4.6 cm) and 2-1/8 (5.4
cm) use a brass spline adapter and screw. For a valve stem height
between 2-1/8 (5.4 cm) and 2-5/16 (5.9 cm) use a plastic spline
adapter.
If the brass spline adapter is required, slide the spline adapter
onto the valve stem and attach with the screw.
If the plastic spline adapter is required, slide the spline adapter
onto the valve stem.
Position the handle assemblies facing in opposite directions away
from the spout.
NOTE: The spline adapter allows fine adjustment of the handle
alignment. To adjust, remove the handle and reposition the spline
adapter.
Align the handle.
Reinstall the handle and check alignment.
Handle
Apply plumbers
putty.
Screw
Brass Spline
Adapter
Valve Stem
Height
Measurement
Plastic
Spline
Adapter
Valve Stem
Valve Body
Threaded
Sleeve
Finished
Surface
Hot
Cold
Orientation Of Handles
In Off Position
Kohler Co. 5 1049621-2-B