Through The Wall Air Conditioner With Supplemental Heater WTC8001W / WTC12001W Owner’s Manual For more information on other great EdgeStar products on the web, go to http://www.edgestar.com To use the EdgeStar self-diagnostic tool, go to https://support.edgestar.com V2.
Important Safety Information Warning: The water produced by the window AC is not potable or suitable for drinking. Do not drink the water drained from the unit as it contains contaminates and could make you sick. Improper handling can cause serious damage to the appliance and/or to the user. Please read the following safety information. Electrical Safety Make sure your hands are dry and not wet before operating the unit. Do not wet the front housing or control panel.
Operation of Safety Plug Note: Electrical products should not be disposed of with household waste. Please contact your local recycling center for more information on how to recycle electronic waste. Your air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) safety plug. This device provides protection to reduce the risk of fire due to arcing faults in the power supply cord.
Table of Contents IMPORTANT SAFETY INFORMATION ............................................................................................................................................. I OPERATION OF SAFETY PLUG ..................................................................................................................................................... II TABLE OF CONTENTS .............................................................................................................................
Introduction Thank you for purchasing this Koldfront by EdgeStar air conditioner. We hope that this purchase will be the beginning of a lasting and rewarding relationship between you and EdgeStar. We will provide the customer support and exemplary products necessary to nurture that relationship. This manual contains important information regarding the proper installation, use, and maintenance of your air conditioner.
Parts Identification Air Conditioner Unit Wall Sleeve (purchased or provided separately) 3
Preparations for Installation Note: You may need to contact an electrician if your room’s circuit is not able to power your unit. Note: To avoid risk of injury and / or product / property damage, please take the following precautions: Two or more people are needed to properly handle and install the unit. Use proper lifting and carrying techniques. Before installation, make sure to inspect the window and sill to ensure they are able to handle the weight and size of this unit.
Installation Instructions Note: When choosing your window make sure power supply cord is within 4 feet of a grounded 3prong outlet. Basic Installation Steps Prepare the Wall Sleeve. Install the rear Louver Panel / Grille into the Wall Sleeve. Attach Seals inside the Wall Sleeve. Prepare the Grounding Wire Insert the Air Conditioner Unit into the Wall Sleeve and attach the Ground Wire. Insert the Main Seal. Attach the Front Frame pieces.
Preparing the Wall Sleeve Your Koldfront Through The Wall Air Conditioner unit is intended to be installed into a compatible wall sleeve enclosure. A wall sleeve provides the proper support and enclosure for your air conditioner and allows for the wall opening to be properly sealed prior to final installation. Note: The Koldfront Through the Wall Air Conditioner Sleeve (Model: WTCSLV) is designed specifically for Koldfront’s line of through the wall air conditioners and can be purchased at www.edgestar.com.
Rear Louver Panel / Grille Installation into Wall Sleeve Diagram Important: Please ensure that the Rear Louver Panel / Grille is installed correctly to ensure proper airflow and performance. Please note the direction and alignment of the louvered fins. Also, please note that when aligned as instructed above, the holes in the louver panel / grille will properly line up to the holes in the Koldfront wall sleeve.
Attach Seals and Support Blocks to Wall Sleeve With the wall sleeve properly assembled, it is now time to prepare the wall sleeve enclosure for the air conditioner unit. The process involves positioning seals and foam support blocks inside of the wall sleeve enclosure in order to enable a proper fit for the air conditioning unit. Important: The below instructions are to be used in conjunction with the Koldfront Wall Sleeve model WTCSLV.
Prepare Ground Wire To properly ground the air conditioner unit, the ground wire must be secured to the frame of the wall sleeve. When the air conditioner unit is placed inside of the wall sleeve, this ground wire will be attached to the air conditioner frame to allow for proper grounding of the air conditioner unit. Note: This step may require the use of a drill with a 1/8” drill bit. If your wall sleeve has been previously installed, there may be no requirement to drill a new hole for the grounding screw.
Install Air Conditioner Unit into Wall Sleeve With the wall sleeve fully prepared, you are now ready to insert the air conditioner unit into the wall sleeve. Two or more people may be required for this step. 1. Remove the cabinet screw on the left lower side of the air conditioner cabinet. Set aside and / or discard the plastic washer. 2. The ground wire will be attached to the air conditioner cabinet using the screw you just removed along with a Toothed Washer. 3.
Completing Installation With the air conditioner installed into the Wall Sleeve and the ground wire properly attached, it is time to complete installation by inserting the Main Insulating Seal (stuffer seal) and attaching the Trim Frame. 1. Locate the Main Insulating Seal (stuffer seal) included with the installation kit. This is the longest seal and measures 1” X 11/2” X 84”.
Alternate and Supplemental Installation Instructions The below instructions may be referenced for scenarios in which the standard installation procedures cannot be followed. Install Rear Louver Panel / Grille Directly on Back of Air Conditioner If your installation scenario does not allow you to attach the Rear Louver Panel / Grille to the Wall Sleeve you may carefully secure the Panel directly to the rear of the Air Conditioner unit. 1. Attach 1” x 3/8” x 14” seal pieces. 2.
Control Panel Operations On/Off Energy Saver Timer Mode Check Filter Fan Speed Sleep Temp/Timer Up Temp/Timer Down Using the Control Panel To Turn the Unit on: Press the On/Off button. Note-The Energy Saver feature will automatically turn on in “Cool”, “Dry”, and “Auto” mode. To Change the Temperature: Press or hold either Up or Down button until desired temperature is seen on the digital display. This temperature will be automatically maintained anywhere between 62 °F (17° C) and 86° F (30° C).
To Select Operating Mode: To choose the operating mode press Mode . Each time you press the button a mode is selected in a sequence that goes from Auto, Cool, Heat, Dry, to Fan. The indicator light beside the mode button will be illuminated and remain on once the mode is selected. Note: Heat function is intended to provide supplemental heating in addition to an existing heat source. The heat function has a lower BTU rating than the cool mode and therefore does not treat the same square footage.
To Use the Energy Saver Feature: To start the Energy Saver feature, press the Energy Saver button. This feature is available on “Cool”, “Dry”, and “Auto”. The fan continues to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which point the compressor turns back on and cooling starts. To Use the Sleep Feature: To initiate, press the Sleep button.
Error Codes AS - Room temperature sensor error Unplug the unit and plug it back in. If the error repeats call for service. Note- In Fan only mode it will display “LO” or “HI”. - Evaporator temperature sensor error Unplug the unit and plug it back in. If the error repeats, call for service. HS - Electric Heating sensor error Unplug the unit and plug it back in. If the error repeats, call for service.
Remote Operations Warning: This product contains a lithium button/coin cell battery which is a potential Chemical Burn Hazard. Keep away from children. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep away from children. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours.
Additional Notes on Remote Operations The remote control has an operating range of 16 ft from the appliance. The remote signal receiver/sensor is located on the control panel of the air conditioner. Reception of signal commands is confirmed by an audible beep. Direct sunlight can interfere with the infrared signal. To replace batteries, remove the back cover by pressing where indicated and sliding off the battery cover.
Maintenance Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up, preventing proper air flow and potentially resulting in an accumulation of frost on the cooling coils.
Normal Sounds High Pitched Chatter - High efficiency compressors may have a high pitched chatter during the cooling cycle. Sound of Rushing Air - At the front of the unit, you may hear the sound of rushing air being moved by the fan. Gurgle/Hiss - Gurgling or hissing noises may be caused by refrigerant passing through the evaporator during normal operation. Vibration - The unit may vibrate and make noise because of poor wall or window construction or incorrect installation.
Troubleshooting Tips Follow the troubleshooting guide below to resolve common issues. Issue My air conditioner is not functioning at all. Possible Cause The wall plug is disconnected. The LCDI power cord is tripped. The house fuse is blown or the circuit breaker is tripped. The air from the unit does not feel cold enough. The control panel is off. Turn the control panel ON and set it to your desired setting. There is insufficient power. Move the unit to another outlet. Check your circuit breaker.
Troubleshooting Tips Continued Issue The air conditioner is cooling but the room is too warm. NO ice is forming on the cooling coil behind the decorative front. Possible Cause The front of the unit is blocked by drapes, blinds, furniture, etc., that restrict air distribution. There are open doors, windows, etc. The unit was recently turned on in a hot room. The air conditioner turns on and off rapidly. There is water dripping INSIDE when the unit is cooling.
Specifications Model Voltage Frequency Plug Type (NEMA) WTC8001W 115V 60Hz 5-15P WTC12001W 208 / 230 60Hz 6-20P BTUs (cooling) 8,000 12,000 / 11,700 BTU’s (heating) 4,200 10,600 / 8,600 Current (cooling) 7.8A 5.5A / 5.9A Current (heating) 12.0A 15.0A / 13.5A Color White White Coolant R410A: 14.81 oz. R410A: 21.87 oz. Timer Dimensions WxDxH Net Weight 24 Hour 24 Hour 24 1/4” x 20 3/8” x 14 1/2” 24 1/4” x 20 3/8” x 14 1/2” 66.6 lbs. 78.3 lbs.
EdgeStar Limited Warranty Full Two-Year Parts and Labor This product is warrantied by EdgeStar and is subject to any conditions set forth as follows: WHAT IS COVERED: For a period of TWO (2) YEARS from the date of original retail purchase, EdgeStar will repair or replace any part free of charge, including labor, that fails due to a defect in materials or workmanship.