Instructions for Use

CHARGING PB BATTERY
Set up the charge current on the left and the nominal voltage of the battery on
the right. The charge current ranges from 0.1 to 5.0A and the voltage should
be matched with the battery being charged.
Start the charge process by pressing Start/Enter key for more than 3 seconds.
The screen displays the state of charging process. To stop charging forcibly,
press Batt type/Stop key once.
The audible sound indicates you at the end of the process.
DISCHARGING PB BATTERY
Set discharge current on the left and final voltage on the right. The discharge
current ranges from 0.1 to 1.0A.
To start the process, press Start/Enter key for more than 3 seconds.
The screen displays the current state of discharge. You can alter the
discharge current by pressing Start/Enter key during the process. Once you
change the current value, store it by pressing Start/Enter button again.
To stop discharging press Batt type/Stop key once. The audible sound indicates you at the end of process.
SAVE DATA PROGRAM
It has a data storage and load program for your convenience. This feature can store up to 5 battery data
by number that represent the individual specification of batteries you are using. They can be called back
for the process of charging or discharging without setting up the program again. To set up the parameter
value in the program, press Start/Enter key to make it blink then change the value with INC or DEC key.
The parameter value setting up in this screen dose not affect charge or
discharge process. They only represent the specification of the battery.
The following screens will automatically be displayed exactly matched with
the battery type you set up. The example shows the battery pack of NiMH,
12 cells and 3000mAh of capacity.
Set up the charge current for manual charge mode, or the current limit for
automatic charge mode. Each mode can be switched by pressing INC and
DEC button at the same time when the current field is blinking.
Setting up discharge current and final voltage.
Setting up the sequence of charge and discharge, and the cycling number.
Saving the data.
Pb Charge
4.0A 12.0V(6P)
Pb-6 4.0A 12.59V
CHG 022:43 00682
Pb DISCHARGE
1.0A 12.0V(6P)
Pb-6 0.4A 12.59V
DSC 022:43 00682
PROGRAM SELECT
SAVE DATA
SAVE [01] NiMH
14.4V 3000mAh
NiMH CHARGE At*
CUR LIMIT 5.0A
NiMH DISCHARGE
1.0A 11.0V
NiMH CYCLE
DCHG>CHG 3
Save . . .
ENGLISH
30
FRAN
Ç
AIS