Instructions for Use

VARIOUS INFORMATION DURING THE PROCESS
You can inquire various information on LCD screen during charging or discharging process. When you press DEC
button the charger shows the establishment of user settings. And also you can monitor the voltage of individual
cell by pressing INC button when the individual connection cable is linked to the Lithium battery being processed.
The final voltage will be reached at the end of process.
Capacity Cut-Off
ON 5000mAh
Safety Timer
ON 200min
The 3-pin port is assigned as an USB port.
The external temperature only will be displayed when using the thermal
probe.
The present voltage of input power.
Using the individual connection cable to the battery, you can check the
individual voltages of each cell in the battery pack. When connect the cable
to the port on the right side of the charger the program shows the voltage
of each cells for maximum 6 cells in sequence. To utilize this feature, the
battery pack must have output connector that linked to each cells.
WARNING AND ERROR MESSAGES
It incorporates various functions of protective and monitoring system to verify functions and the state of its
electronics. In any case of occurring error, the screen displays the cause of error that is self-explanatory
with audible sound.
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the connection
between battery and output or voluntarily disconnecting the charge lead
during the operation of charge or discharge on output.
There was a short-circuit at OUTPUT. Please check the charging leads.
End Voltage
12.6(3S)
USB/Temp Select
USB Enabled
Ext.Temp 26C
IN Power Voltage
12.56V
4.14 4.16 4.09
0.00 0.00 0.00
REVERSE POLARITY
CONNECTION BREAK
SHORT ERR
ENGLISH
32
FRAN
Ç
AIS