User's Manual

Table Of Contents
RADius 1000 Installation Manual, rev. 5 Installation
20
NET
MOUSE
KEYB
VGA
PPS
AUX - Serial
LPT1
MRU
grounded outlet only
Compass safe distance:
Steering Magnetic Compass : 1.1 m
Standard Compass : 1.9 m
: 100-240VAC/47-63Hz/100VA
: Must be connected to
: 2A
Input
Fuse
Class1
COM 6
COM 7 COM 10
COM 9
COM 2 COM 5 COM 8
Figure 10 Rear panel of the Processing Unit
3.4.2.1 External output serial lines
RADius communicates with external equipment through RS-232 and RS-422 serial lines.
Output data are distance and bearing to dynamic positioning systems etc., hereafter called
host systems. No hardware or software handshake is used on the serial lines.
The configuration of serial lines and their default settings are:
Line Type Data
com5 RS-232 User configurable output
com6 RS-232 User configurable output
com7 RS-422 User configurable output
com8 RS-422 User configurable output
com9 RS-422 User configurable output
com10 RS-422 User configurable output