RADius 1000 Installation Manual, rev. 5 Installation
25
For the cable connections in the Transponder Power Supply, see the figure below. The cable
marked DC is the cable to the Transponder and the cable marked AC is the VAC input. The
shield wire to the Transponder is not connected in the Transponder Power Supply.
G
N
L
+6 V
+6 V
0 V
0 V
7
6
5
4
3
2
1
DC AC
Pair 1
Pair 2
Figure 18 Transponder Power Supply cable connections
WARNING! The power to the Transponder Power Supply is Class 1
equipment and must be properly connected to a grounded
mains outlet!
3.4.2.6 Low Power Transponder battery switch
Please note that the RADius 500 Transponder needs an LP-Transponder activate switch
installed in the connector position on the rear side for applying the battery power.
WARNING! NEVER connect other equipment than the supplied battery
switch to the rear connector. An attempt to connect other
sources to the connector pins may cause a hazard.
3.4.2.7 Interrogator Cable installation procedure
1. Connect the power cable connector to the rear of the Interrogator Unit and the other end
of the cable to the Power terminal list on the Power/Connection Shelf. Shields shall be
connected in the provided terminals. The shield terminals on the connection shelf are
floating. Shields are terminated inside the Interrogator Unit.