1�3 Safety precautions
Read all safety precautions thoroughly before using
this device.
Be sure to observe the safety precautions described in
this section.
1�3�1 Precautions before usage
CAUTION
The operators (hospitals and clinics) hold responsibility
for the usage and maintenance of this device. Do not
use this device unless you are a physician or certied
person under law.
This device excluding the image processing controller is
suitable for use in the patient environment. (PC used for
the image processing controller is not suitable for use in
the patient environment.)
Confirm that this device is operating normally before
using.
When a problem occurs with this device, turn the power
o󰀨, attach an appropriate sign, such as "malfunction",
on this device, and contact Konica Minolta technical
representatives.
This device is not explosion-proof, so do not use any
ammable or explosive gas near this device.
For the basic operation of the computer, display moni-
tor, and optional parts for this device, refer to their op-
eration manuals.
Please follow the rules and regulations of your relevant
authorities in the disposal of this product, accessories,
options, consumables, media and their packing materi-
als.
This symbol means: Do not dispose of this
product together with your household waste!
Please refer to the information of your local
community or contact our dealers regarding
the proper handling of end-of-life electric and
electronic equipments.
Recycling of this product will help to conserve
natural resources and prevent potential negative
consequences for the environment and human
health caused by inappropriate waste handling.
1�3�2 Precautions for usage
WARNING
The DR Detector is a precision instrument. If it is
dropped or hit against any object, a failure may occur
due to strong impact or excessive load.
Take note of the following when using this device:
Do not subject the DR Detector to strong shocks or
excessive loads by dropping it, etc.
Do not exceed the specied overall load range when
applying a load to an DR Detector.
Do not disassemble or modify this device.
Do not connect any devices that were not purchased
from Konica Minolta.
Do not turn the power switch o󰀨 or pull out the power cable,
Ethernet cable while the system is operating.
Be careful not to drop the DR Detector on any part of a per-
son's body by catching the wired cable on your feet.
Do not lean on or put pressure on the AeroDR Bat-
tery Charger installed on a wall.
The wired cable is connected to the DR Detector using mag-
netic force. When moving the DR Detector, do not hold onto the
wired cable, and always hold on the DR Detector. Also, do not
grasp and pull the DR Detector forcefully.