Service Manual
DRUM UNIT
3-35
III DIS./ASSEMBLY
A. Procedure
1. Remove the transfer and separation corona unit
from the main body.
2. Use a tweezers to remove the hook [1] from the
transfer and separation corona unit. Then
remove the plunging prevention plate [2].
3. Remove the spark arrestor plates/F [1], /R [2].
4. Move the cleaning block to home position, and
remove the top covers [1] from the cleaning
block.
5. Remove the spring [2] from each wire, and
remove the wires [3].
Note:
• When removing the wire, be careful that the wire
holding rubber that is in touch with the V-shaped
rack [4] does not get lost.
6. Reinstall the above parts following the removal
steps in reverse.
Note:
• When installing the wire, be sure that the cleaning
block is in home position at the right side. Stretch
the wire so that it fits into the V holders [4].
[1]
[2]
[1]
[2]
[1]
[2]
[3]
[4]
[4]