Service Manual

FIXING UNIT
3-64
III DIS./ASSEMBLY
2
9.6 Removing and Reinstalling
the Fixing Temperature Sen-
sors
Caution:
After installing the fixing temperature sen-
sors:
Make sure that the wire bundles are not in
contact with the fixing heat roller.
Make sure that the sensors them-selves (the
sensor areas) are in contact with the fixing
heat roller.
A. Periodically replaced parts/cycle
Fixing sensor assembly: Every 480,000 copies
(7145)
Fixing sensor assembly: Every 400,000 copies
(7235/7228/7222)
B. Procedure
1. Remove the fixing unit from the main body.
2. Remove the fixing claw unit.
3. Remove the fixing web.
4. Remove the connector [1].
5. Remove the 3 screws [2], and remove the fixing
web mounting piece [3].
6. Remove the 2 screws [4], and remove the fixing
sensor assembly [5].
7. Reinstall the above parts following the removal
steps in reverse.
Note:
The fixing sensor assembly [7] is made up of the
TH1 (fixing temperature sensor/1) and the TH2
(fixing temperature sensor/2). Since the TH1 and
the TH2 have been adjusted at the time of their
assembling, avoid surely loosening the screws.
Make sure that the sensors are in contact with the
heat roller.
[1]
[7]
[2]
[3]
[4]
[5]
[6]
[4]