Service Manual

I ADJUSTMENT
25 MODE
1-31
3
3. “PM count/cycle setting screen”
Press the [3. Counter clear] key.
4. “Counter clear screen”
Press the key corresponding to the item to be
cleared.
5. Message in the message display area will con-
firm if you really want to clear the item. Press
the [YES] key. When the item is cleared, the
“Counter clear screen” will be restored.
6. When clearing another counter, repeat above
steps 3 and 4.
7. Press the [RETURN] key twice to return to the
“25 mode menu screen”.
7.4 Data Collection
This function enables viewing of the various data
recorded in the machine. Also, it is possible for the
collected data to be checked by KRDS and man-
agement listing. The data collection menu includes
the following:
Count data collection
Area data collection start (Date count data)
A. Data that can be checked
Note:
When the DIPSW8-7 is set to 0, the checking of
the collected data is limited only to No. 1.
B. Checking method of the collected data
(1) Procedure
1. Enter the 25 Mode.
2. “25 mode menu screen”
Press the [Data collection] key.
3. “Data collection menu screen”
Press the [Count data] key.
4. “Data collection screen”
Change the data number with the arrow key.
Pressing [NEXT] key enables display of next
data collection screen.
5. Press the [RETURN] key to return to the data
collection menu screen.
The data is displayed at the line 2 in the mes-
sage display area as “Data number (No.): Count
value (00000000)”.
Press and hold the arrow key to display the next
items continuously.
Note:
In order to check the collected data 2 to 4, be
sure to make preparations given in “Collected
data list” in advance.
No. Classification Pre-peration
1 Copy count of each
paper size
RADF paper pas-
sage count
2 Count of JAM occur-
rence by each point
Enter the 25 mode
Select
[1. Software SW]
Set the address to
8-7:1 (Note)
3 Copy count of each
mode
4 Count of SC occur-
rence