D. Starting periodic date collection
Reset the periodic data from the setting peri-
odic collection start date. Make a date that this
operation is performed as a new periodic col-
lection start date.
The periodic data can be checked with the
KRDS/RDmode (7145) and management list.
(1) Procedure
1. Enter the 25 mode.
2. “25 mode menu screen”
Press the [3. Collecting data] key.
3. “Data collection menu screen”
Press the [2. Starting periodic data collection]
key.
4. “Starting periodic data collection screen”
Press the [YES] key to start the periodic data
collection.
Press the [NO] or [RETURN] key, then data col-
lection start date is not reset and returns to the
data colleciton menu screen.
7.5 Copy Count for Each Part to
be Replaced
Perform the copy count display, count clear, limit
value setting and arbitrarily parts to be replaced set-
ting to the data of the parts to be replaced (fixed/
arbitrarily).
Each count value can be check with the manage-
ment list of 36 Mode and the KRDS/RDmode
(7145). The following are included in the part
counter menu:
Copy Count for each fixed replacement part
Copy Count for each arbitrarily replacement part
7.5.1 Copy count by parts to be replaced (fixed)
Set the parts name of the fixed parts to be replaced
(fixed), parts No. and copy count display, and count
reset.
A. Procedure
1. Enter the 25 Mode.
2. “25 mode menu screen”
Press the [4. Parts counter] key.
3. “Parts counter menu screen”
Press the [1. Count of parts (Fixed)] key.
4. “Copy count screen by parts to be replaced
(fixed)”
Press the arrow keys to select the data.
5. Press the [Count reset] key.
6. “Count reset screen by parts to be replaced
(fixed)”
Press the [YES] key to clear the copy count.
Press the [NO] or [RETURN] key, then the copy
count is not reset and returns to the copy count
screen by parts to be replaced.