Service Manual

I ADJUSTMENT
OTHER ADJUSTMENTS
1-108
1
10.14 Staple Position Adjustment
of FS-114
It is replaced when the stapler is replaced or
when the staple position is not correct.
A. Procedure
1. Set the staple mode and make a copy.
2. Check the staple position of the paper.
1-Point Tilted Staple
Paper Width 279 to 297mm: 45° tilt
B5, B4: 30° tilt
1-Point Parallel Staple
Paper Width 182 to 216mm
Measurement
position
Specification Adjustment range
A, D 4.4 ± 3mm
B, C 12.1 ± 4mm +1mm to -2mm
Measurement
position
Specification Adjustment range
A 4.9 ± 3mm
B 16.2 ± 4mm +1mm to -2mm
C 10.1 ± 4mm +1mm to -2mm
D 6.5 ± 3mm
Measurement
position
Specification Adjustment range
A 4.5 ± 3mm
B 6.0 ± 4mm +1mm to -2mm
A
B
C
D
4349D503AA
A
B
4349D504AA