Service Manual

SCANNER SECTION
3-14
III DIS./ASSEMBLY
3.4 Removing the Platen Glass/
Slit Glass
When removing the platen glass, execute only the
steps 1, 3, 7, 8 and 9 in the following procedure. For
the slit glass, execute all of the steps 1 to 9.
A. Procedure
1. Open the RADF.
2. Remove the operation unit.
3. Remove the 4 screws [1] and remove the scan-
ner exterior/R [2].
4. Remove the 4 screws [1] and remove the scan-
ner exterior/L [2].
[1]
[1]
[2]
[1]
[1]
[2]