CONTENTS Getting Started ----------------------------------------------------------------------2 Setup Procedures --------------------------------------------------------------------3 Setup Menu------------------------------------------------------------------------------4 Setup flow Chart -----------------------------------------------------------------------4 Group 0 : Interface Selection ------------------------------------------------------5 Group 1 : Device Selection for keyboard interface-------------
Getting Started Installing Keyboard Wedge Scanner To install a keyboard wedge scanner, follow the steps listed below: 1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or terminal) 2) Turn off the power of the system 3) Unplug the keyboard from the system 4) Connect the Y (U)- cable to the system and keyboard 5) Turn on the power of the system 6) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading Installing a RS-232 Interface Scanner To insta
Setup Procedures 1) Locate a group that contains the parameters to be changed. 2) Scan the “Enter Group #” label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the “Exit” to end the group currently selected, the scanner will sound beeps.
Setup Flow Chart ENTER GROUP SELECT ITEMS EXIT Set All Defaults Show Version 4
Group 0: Interface Selection ENTER GROUP EXIT KEYBOARD RS-232 WAND OCIA RS-232 Reserved 2 DTMF Reserved 4 5
Group 1: Device Selection for Keyboard Interface ENTER GROUP EXIT PC/AT, PS/2 50,60,70,80(*) PC/XT PS/2 25, 30 (NEC 9801) (IBM 5550) (PS 55) (NEC N5520) (ACER 7300) (KW1050D/CT-700A/WANG 5120) (WANG 5425) (MAC_SE) (LC-6533) 6
Group 1: Device Selection for Keyboard Interface ENTER GROUP EXIT (IBM3196,3197,3476,3477) Reserved Q Reserved R Reserved T IBM3197 IBM 3476 IBM3477 RESERVED 5 Reserved 6 RESERVED 7 Reserved 8 RESERVED 9 7
Group 2: Intercharacter Delay ENTER GROUP EXIT Start Keyboard Setting Scan Enter Group 2 Label -- > Scan Start Keyboard (or RS-232) Setting Label --> Scan two digits labels in "Table-Hex" --> Scan Exit Label Start RS-232 Setting Keyboard Default Value: 05 RS-232 Default Value : 00 8
Group 3: Language for Keyboard Interface ENTER GROUP EXIT U.S.
Group 3: Language for Keyboard Interface ENTER GROUP EXIT CANADA HOLLAND POLAND LATIN JAPAN RESERVED 1 RESERVED 2 RESERVED 3 (IBM THINK-PAD FOR JAPAN) (PANASONIC CF-II FOR JAPAN) 10
Group 4: Terminator ENTER GROUP EXIT KEYBOARD NONE CR SPACE TAB ESC CTRL-C ESC 11
Group 4: Terminator ENTER GROUP EXIT RS-232 NONE CR CR/LF LF SPACE TAB ESC CTRL-C STX..ETX XON..
Group 5: Scan Mode ENTER GROUP EXIT 1: Trigger On/Off 2: Trigger On/Good Read Off (*) 3: Trigger On/Good Read Off/ Delay Timeout = ? 4: Continuous/Trigger Off 5: Continuous/LED Always on 6: Continuous/No Trigger 7: Continuous/Testing 8: Continuous/Trigger Off/ Delay Timeout = ? 13
Group 5: Scan Mode ENTER GROUP EXIT FLASH OFF(*) FLASH ON SHORT ZONE LONG ZONE LASER DELAY For Laser Scanner Mode Default Laser Delay Timeout = 60 sec. Scan Enter Group 5 Label Scan Laser Delay --> Refer to the Table-Hex at page 41 and select a value --> Scan Confirm in Table Hex.
Group 6: Preamble and Postamble ENTER GROUP EXIT Preamble Postamble Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII Table(page 44), scan two digits in Table-Hex (Page 43) Representing one character, maximum 10 characters can be accepted.
Group 8: RS-232 Parameters ENTER GROUP EXIT Baud Rate 300 600 1200 2400 4800 9600(*) 19200 38400 Data Bit BIT 7 BIT 8 16
Group 8: RS-232 Parameters ENTER GROUP EXIT Parity : NONE (*) ODD EVEN Handshaking: NONE (*) XON/OFF Scanner Ready Data Ready ACK/NAK 17
Group 8: RS-232 Parameters ENTER GROUP EXIT (CK/NAK Response Time CTS Observation Time:) 100 ms 300 ms 500 ms 1 sec. 3 sec (*) 5 sec. 10 sec.
Group 9: CODE 39 / (CODE 32) ENTER GROUP EXIT Enable (*) Disable Standard (*) Full ASCII Transmit Start/End Character Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Enable CODE 32 19
Group 9: CODE 39 / (CODE 32) ENTER GROUP EXIT Verify Normal (*) Verify Strick 20
Group 10-1: Interleaved 2 OF 5 ENTER GROUP EXIT Disable (*) Enable Transmit Check Character Disable Enable (*) Verify Checksum Disable Enable Length Define Barcode Length Setting Min: 4 Max: 48 Scan Enter Group 10-1 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exit Label User Define 3 Sets Available User Define Length Setting: Scan Enter Group 10-1 Label Scan User Define Label--> Scan Six Digit Labels in Table Hex (O
Group 10-2: Industrial 2 OF 5 / IATA ENTER GROUP EXIT Disable (*) Enable Transmit Check Character Disable Enable (*) Verify Checksum Disable Enable Length Define Barcode Length Setting Min: 2 Max: 24 Scan Enter Group 10-2 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exit Label User Define 3 Sets Available User Define Length Setting: Scan Enter Group 10-2 Label Scan User Define Label--> Scan Six Digit Labels in Table H
Enable Group 10-3: Matrix 2 of 5 ENTER GROUP EXIT Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Length Define Min: 2 Barcode Length Setting Max: 40 Scan Enter Group 10-3 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exit Label User Define 3 Sets Available User Define Length Setting: Scan Enter Group 10-3 Label Scan User Define Label--> Scan Six Digit Labels in Table He
Scan Confirm Label in Table Hex --> Scan Exit Label Group 10-4: CHINA POSTAGE ENTER GROUP EXIT Disable (*) Enable Transmit Check Character Enable (*) Disable Verify Checksum Enable Disable (*) Length Define Min: 2 Barcode Length Setting Max: 40 Scan Enter Group 10-3 Label --> Scan Length Define Label --> Scan Four Digit Labels in Table Hex (Page 43) --> Scan Confirm Label in Table-Hex --> Scan Exit Label User Define 3 Sets Available User Define Length Setting: Scan Enter Group 10-3 Label Scan User Def
Scan Confirm Label in Table Hex --> Scan Exit Label Group 11: CODE 128/(CODE 93)/(CODE 11)/(MSI-PLESSEY) ENTER GROUP EXIT CODE 128 Enable (*) Disable CODE 93 Enable Disable (*) Concatenation Enable Disable (*) 25
Note: Options marked by ( ) are only available upon request Group 11: CODE 128/(CODE 93)/(CODE 11)/(MSI-PLESSEY) ENTER GROUP EXIT Enable(*) Disable Number of Check Character One Two (*) Transmit Check Character Enable Disable (*) MSI/PLESSEY Enable (*) Disable 26
Note: Options marked by ( ) are only available upon request Group 12: (ISBN/ISSN) ENTER GROUP EXIT Disable (*) Enable 27
Note: Options marked by ( ) are only available upon request Group 13: CODABAR / NW7 ENTER GROUP EXIT Enable(*) Disable Transmit Start/End Character Disable (*) Enable Start/End Transmit Type ABCD/ABCD ABCD/TN*E abcd/abcd (*) abcd/tn*e 28
Group 14: (Code 4) ENTER GROUP EXIT Enable Disable (*) 29
Note: Options marked by ( ) are only available upon request Group 15-1: EAN-13/JAN-13 ENTER GROUP EXIT Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable Truncate Leading Zero Disable (*) Enable 30
Check-Digit On (*) Check-Digit Off Group 15-2: UPC-A ENTER GROUP EXIT Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable Truncate Leading Zero Disable (*) Enable 31
Group 15-3: EAN-8/JAN-8 ENTER GROUP EXIT Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Disable (*) Enable EAN Convert to EAN-13 Disable (*) Enable 32
Group 15-4: UPC-E / UCC EAN/128 ENTER GROUP EXIT Enable (*) Disable ADD-ON 2/5 Disable (*) Enable (*) Transmit Check Character Disable Enable (*) Truncate Leading Digit Disable (*) Enable UCC/EAN/128 Disable (*) Enable UPC-E Convert to UPC-A 33
Disable Enable Group 16: General Parameters ENTER GROUP EXIT Upper Case Lower Case Universal ALT Mode Buzzer Pitch (Default : 16) Buzzer Duration (Default: 04) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Group 16 Label --> Scan Buzzer Pitch or Buzzer Duration Label --> Scan Two Digit Labels in Table-Hex --> Scan Confirm Label in Table-Hex --> Scan Exit Label Power Up Beeping Disable Enable (*) 34
Turbo (*) Normal Group 17: Code ID Setting ENTER GROUP EXIT CODE 39 INTERLEAVED 2 OF 5 INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 CHINA POSTAGE CODE 128 CODE 93 CODE 11 MSI/PLESSEY CODABAR/NW7 EAN-13/UPC-A EAN-8 UPC-E UPC-A 35
Note: Refer to ASCII Table, scan two hexadecimal labels in Table Hex to represent one character Group 18: WAND Type Parameters ENTER GROUP EXIT BAR=LOW BAR=HIGH(*) Scan Speed Lowest Low (*) High Highest Data Format Transmit in Normal Format (*) Transmit in Code 39 Format Transmit in Code 128 Format 36
Group 19-1: (Magnetic Parameters) ENTER GROUP EXIT Disable Enable (*) Track Order Track 1/2/3 (*) Track 1/3/2 Track 2/1/3 Track 2/3/1 Track 3/2/1 Track 3/1/2 37
Note: Options marked by ( ) are only available upon request Group 19-1: (Magnetic Parameters) ENTER GROUP EXIT Track Selection Track 1&2&3 any (*) Track 1 only Track 2 only Track 3 only Track 1 and 2 Track 2 and 3 Track 1 and 2 and 3 ISO (*) (JIS-2) 38
Note: Options marked by ( ) are only available upon request Group 19-2: (Magnetic Parameters) ENTER GROUP EXIT Start Sentinel: (SS) Tk1 Default : % Tk2 Default Tk3 Default: ; ? End Sentinel: (ES) Tk1&2&3 Default: ? DLE: Tk1 Default : Null Tk2 Default: Null Tk3 Default: Null STX: Tk1&2&3 Default: Null Magnetic Output Data Format: 39
STX - Tk1 Start Sentinel - Tk1 Data - End Sentinel - Tk1 - DLE STX - Tk2 Start Sentinel - Tk2 Data - End Sentinel - Tk2 - DLE STX - Tk3 Start Sentinel - Tk3 Data - End Sentinel - Tk3 - DLE Note: Options marked by ( ) are only available upon request Group 20: (Function Key Emulation) ENTER GROUP EXIT Enable Disable (*) Enable Function Key Emulation: Scan Enter Group 20 Label --> Scan Enable Label --> Scan Exit Label 1: To concatenate a function key with input data, please refer to Function Key Table for i
2: To scan a function key barcode label, full CODE 39 must be enabled. Please refer to Full CODE 39 Table to produce the function key barcode label.
Function Code for PC XT/AT Enter ($M) End ($U) ($B) Tab ($N) PgUp ($V) BS ($O) PgDn ($W) Up ($P) Ins ($X) Down ($Q) Del ($Y) Left ($R) Esc (%A) Right ($S) 42
Home ($T) Table-Hex : HEXADECIMAL 0 1 2 3 4 5 6 7 8 9 A B C D 43
E F Confirm ASCII TABLE 44
Hexadecimal-Decimal Conversion Table 45
For Example: Hexadecimal 56 -> H:5 L:3 D5-> H:D L:5 PIN ASSIGNMENTS COLOR Function Start of Scan 9 Pin DSUB/AM 25 PIN P (F) DIN(M) 6 PIN 6 PIN DIN MINI DIN (M) (M) 1 --- 6 6 Signal Data Led Indicator 2 2 2 4 3 --- --- --- 5 5 5 1 Green Trigger Power Enable 6 4 4 2 Black GND 7 3 3 5 VCC+5V 9 1 1 3 Yellow Orange White Blue Red Wand Emulation Signal Output 9 PIN DSUB/AM 5 PIN DIN P (F) (M) 6 PIN DIN (M) COLOR Function Orange Signal Data 2 2 2 Black GND 7 3
PIN ASSIGNMENTS RS-232 Signal Output COLOR FUNCTION 9 PIN DSUB/AMP(F) 25PIN DSUB(F) Black GND 5 7 Brown CTS 7 4 Grey RTS 8 5 Violet RX 3 2 Green Red TX 2 3 VCC+5V 9 25 Note : For PC applications , a cable with DC power jack is required to accept external power input.