General
Vibration Designed to meet or exceed the following:
Bellcore GR-63, Section 4.4
Operating: 1.0G, 5-500Hz each axis
Non-operating: 0.5G, 5-50Hz, 3.0G, 50-500Hz each axis
Shock Designed to meet or exceed the following:
DIN/IEC 60068-2-27
Bellcore GR-63, Section 4.3
30G, half-sine 11ms, each axis
Safety Designed to meet or exceed the following:
UL 60950, 3rd edition
EN 60950
LVD 73/23/EEC
Denan Law
EMC Designed to meet or exceed the following:
FCC 47 CFR Part 15, Subpart B
EN55022, EN55024
EN 300 386
Reliability
MTBF: > 176,000 hours @ 40°C/104°F (Telcordia SR-332, Issue 1)
HW Monitoring
LEDs ATCA LEDs:
4 LEDs ("Ready for Hot Swap", "Out of Service", "Healthy", "Heart Beat")
Board Management
based on IPMI 1.5
FRU Management
Sensors (Voltage, Current, Temperature, Fuse)
Status and Alerting
Hot Swap Management for Base Board and AMC
Electronic Keying of Base and Fabric Interfaces and AMC ports
Local SEL
Table 1-2: AT8402 Main Specifications (Continued)
AT8402 SPECIFICATIONS