User Manual Manual
AT8402 Introduction
Page 1 - 9 AT8402 User Guide
General
Vibration Designed to meet or exceed the following:
• Bellcore GR-63, Section 4.4
• Operating: 1.0G, 5-500Hz each axis
• Non-operating: 0.5G, 5-50Hz, 3.0G, 50-500Hz each axis
Shock Designed to meet or exceed the following:
• DIN/IEC 60068-2-27
• Bellcore GR-63, Section 4.3
• 30G, half-sine 11ms, each axis
Safety Designed to meet or exceed the following:
• UL 60950, 3rd edition
• EN 60950
• LVD 73/23/EEC
• Denan Law
EMC Designed to meet or exceed the following:
• FCC 47 CFR Part 15, Subpart B
• EN55022, EN55024
• EN 300 386
Reliability
• MTBF: > 176,000 hours @ 40°C/104°F (Telcordia SR-332, Issue 1)
HW Monitoring
LEDs ATCA LEDs:
• 4 LEDs ("Ready for Hot Swap", "Out of Service", "Healthy", "Heart Beat")
Board Management
• based on IPMI 1.5
• FRU Management
• Sensors (Voltage, Current, Temperature, Fuse)
• Status and Alerting
• Hot Swap Management for Base Board and AMC
• Electronic Keying of Base and Fabric Interfaces and AMC ports
• Local SEL
Table 1-2: AT8402 Main Specifications (Continued)
AT8402 SPECIFICATIONS