Chef Bases KCB-53-2M KCB-60-2M KCB-74-4M KCB-83-4M KCB-96-4M Visit us on the web at www.mvpgroupcorp.com 5659 Royalmount Ave. Montreal,QC H4P2P9 12000 Biscayne Blvd.
Contents ♦ Specifications ……………………………….... 3 ♦ Installation ……………………………………. 4 ♦ Maintenance & cleaning …………………….. 4 ♦ Operation & Installing Castors …………..... 5 ♦ Trouble-Shooting …………………………….. Visit us on the web at www.mvpgroupcorp.
Specifications P d t Product Chef Ch f Bases Model KCB-53-2M KCB-60-2M KCB-74-4M KCB-83-4M KCB-96-4M Capacity (cu.ft) Exterior Dimensions (Including 4” Casters) [in] N tW Net Weight i ht (lb (lbs)) 9.8 9.8 14.3 17.2 21.4 W 52 8 52.8 60 74 83 3 83.3 96.1 D 30.5 30.5 30.5 30.5 30.5 H 25.1 (25.5) 25.1 (25.5) 25.1 (25.5) 25.1 (25.5) 25.1 (25.5) 236 262 304 342 363 Rated Voltage AC115V /60Hz Type of Power Cord NEMA 5-15P Amps 3.3 3.3 3.3 6.0 6.
Installation 1. INDOOR USE ONLY • This unit is intended for indoor use only. 2. FOR LOCATION • Be sure that the location is strong enough to support the total weights of the unit and the content. • Keep the unit away from sunlight and other heat generating equipment. • The minimum clearance between the back of the unit and the wall should be 7 inches at least. 3. INSTALLING CASTORS • Be sure that castors with brake should be installed in front. 4.
Operation 1. The temperature p controller ((thermostat)) is located on the upper pp left of the back side of the cabinet interior. 2. The controller has been preset "NORMAL" position at the factory. 3. Set the control-knob toward "COOL" for higher temperature and "COLD" for lower temperature. 4. The thermostat controls compressor's ON/OFF by sensing inside temperatures of cabinet. cabinet 5. The unit is equipped with an off-cycle defrost . Installing g Casters 1. Remove the outer packing. 2.
Troubleshooting Problem Possible Cause Action Power connection failure. Check Power Cord and plug it in. Power switch is in off position. Change it on position. Temperature set point is too high. Correct temperature set point. The door is opened too frequently. Do not open the door Frequently. Loading of too much warm or moist product. Do not load warm or moist product. Not enough ventilation. Move the unit in a well ventilated place with at least 7 inches of clearance on all sides.
MEMO Visit us on the web at www.mvpgroupcorp.
MVP GROUP CORPORATION MVP GROUP CORPORATION 5659 Royalmount Ave. 12000 Biscayne Blvd. Ste 108 Montreal, QC, Canada Miami,FL USA 33181 H4P 2P9 Telephone : (514) 737-9701 Toll Free Telephone : (888) 275-4538 Fax : (514) 342-3854 342 3854 Toll Free Fax : (877) 453-8832 Email : service@mvpgroupcorp.com Website : www.mvpgroupcorp.com Visit us on the web at www.mvpgroupcorp.