SANDWICH/SALAD TABLE & MEGA TOP UNDERCOUNTER REFRIGERATOR UNDERCOUNTER FREEZER Visit us on the web at www.mvpgroupcorp.
CONTENTS SPECIFICATIONS ------------------------------------------ 3~ 5 INSTALLATION ------------------------------------------- 6 MAINTENANCE & CLEANING ----------------------------- 7 OPERATION 7 ----------------------------------------------- TROUBLESHOOTING ------------------------------------- INSTALLING CASTORS --------------------------------- 2 8 9
SPECIFICATIONS – SANDWICH/SALAD TABLE, MEGA TOP PRODUCT SANDWICH/SALAD TABLE Model Capacity (cu ft) KST-1 KST-2 KST- KST-3 7 12 16 19 Exterior Dimension (in) W 27 1/2 48 1/4 60 1/3 72/ 2/5 (excluding castor 5") D 30 30 30 30 H 36 1/2 36 1/2 36 1/2 36 1/2 198 284 316 348 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 3.4A 6.0A 6.0A 6.1A Compressor 1/5HP 3/8HP 3/8HP 3/8HP Refrigerant R-134a R-134a R-134a R-134a Net Weight (lbs) Power Voltage Amps.
SPECIFICATIONS – UNDERCOUNTER REFRIGERATER PRODUCT UNDERCOUNTER REFRIGERATOR Model KUCR-1 KUCR-2 KUCR- KUCR-3 7 12 16 19 W 27 1/2 48 1/4 60 1/3 72 2/5 D 30 30 30 30 H 29 3/4 29 3/4 29 3/4 29 3/4 185 264 309 353 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 3.2A 6.0A 6.0A 6.1A Compressor 1/5HP 1/5HP 3/8HP 3/8HP Refrigerant R-134a R-134a R-134a R-134a Capacity (cu ft) Exterior Dimension(in) (excluding castor 5") Net Weight (lbs) Power Voltage Amps.
SPECIFICATIONS – UNDERCOUNTER FREEZER PRODUCT UNDERCOUNTER FREEZER Model Capacity (cu ft) KUCF-1 KUCF-2 KUCF- KUCF-3 7 12 16 19 Exterior Dimension (in) W 27 1/2 48 1/4 60 1/3 72 2/5 (excluding castor 5") D 30 30 30 30 H 29 3/4 29 3/4 29 3/4 29 3/4 194 282 326 370 115V/60Hz 115V/60Hz 115V/60Hz 115V/60Hz 5.3A 7.5A 7.5A 7.8A Compressor 3/8HP 1/2HP 1/2HP 1/2HP Refrigerant R-134a R-404a R-404a R-404a Net Weight (lbs) Power Voltage Amps.
INSTALLATION 1. INDOOR USE ONLY * This unit is intended for indoor use only. 2. FOR LOCATION Be sure that the location has enough floor space to support the total weight of the unit and its contents. Keep the unit away from sunlight and other heat generating equipment. The minimum clearance between the back of the unit should be at least 7 inches from wall. 3. INSTALLING CASTORS The Castors with brakes should be installed in front. 4. LEVELING The unit should be level to provide adequate drainage. 5.
MAINTENANCE & CLEANING 1. To maintain proper refrigeration performance, the Condenser Fans should be checked monthly and cleaned with a soft brush or vacuum cleaner as needed. 2. Wait at least 6 minutes after unplugging the unit before re-starting. 3. The interior and exterior of the unit can be cleaned using warm water. Do not use an abrasive cleaner in order to prevent scratches on the surfaces. 4. The Door-Gasket should be cleaned frequently to maintain proper sealing. OPERATION 1.
TROUBLE SHOOTING Problem Compressor does not start Possible Cause Action Power connection failure Check Power Cord and plug it in Power Switch is in OFF position Move Power Switch to ON position (KUCF-2, 60, 3 ) Temperature set point is too high Correct temperature set point The door is opened too frequently - Loading of too much warm or moist The unit does not refrigerate well product Move the unit to well ventilated Ventilation is not enough area with at least 7 inches of Clearance in the
INSTALLING CASTORS 1. Remove the outer packing. 2. Install the Castors in the nut area. 3. Make sure that Castors with brakes are installed in front.
MEMO Visit us on the web at www.mvpgroupcorp.
MEMO Visit us on the web at www.mvpgroupcorp.
MVP GROUP CORPORATION 5659 Royalmount Ave. Montreal, QC, Canada H4P 2P9 Telephone : (514) 737-9701 Toll Free Telephone : (888) 275-4538 Fax : (514) 342-3854 Toll Free Fax : (877) 453-8832 Email : sales@mvpgroupcorp.com Website : www.mvpgroupcorp.