® Superior Liquid Cooling Systems www.koolance.com RP-985, RP-1005 User’s Manual English v1.
This User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/support GENERAL PRECAUTION Please read this manual carefully before beginning the installation of your Koolance system. This manual assumes the user has basic experience in building and configuring computer systems. Information referring to traditional hardware assembly is intentionally brief.
! WARNING: The Koolance liquid & coolant pack contain chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICALS OUT OF THE REACH OF CHILDREN. If ingestion has occurred, seek medical attention immediately. Give two glasses of water. Do not induce vomiting. In the case of eye contact, flush eyes immediately with water for 15 minutes. Remove contact lenses. Call a physician if irritation persists.
Included Hardware - Temperature Sensors (x3) - ATX Pass-Thru Wire - Mounting screws - ATX Jumper Wire - User Manual Required Tools During installation, you may need the following tools: Chapter flat-head screw driver 1 System Features phillips-head screw driver pliers long-nose pliers scissors iv User Manual 1
Unit Diagram Display Panel ! Reservoir CAUTION: This cooling system allows full user control of hardware safety settings, such as audio alarm, shutdown, and pump speed. Please be sure to configure your LED Display Panel properly, or damage to your computer, data, and/or equipment could result. Increase Setting Current Mode Value Decrease Setting Mode Select Control Buttons Display in ºC or ºF Modes Display There are seven display options.
the ▼ or ▲ buttons to adjust pump settings, or hold down an arrow to skip to the lowest or highest mode directly. There is no automatic mode for the pump. RP-1005 Manual Mode Auto Mode Temperature Range Fan Duty μs Fan Power % Pump Voltage Pump Power % 1 0 - 35ºC (32 - 95ºF) 5 20 7.68 60 2 36 - 37ºC (97 - 99ºF) 6 24 7.83 62 3 38 - 39ºC (100 - 102ºF) 7 28 8.08 64 4 40 - 41ºC (104 - 106ºF) 9 36 8.36 66 5 42 - 43ºC (108 - 109ºF) 11 44 8.
Positioning the Unit The cooling unit is designed to operate in one orientation. In other directions, the pump and reservoir may not bleed properly and could lead to cavitation. Chapter 2 YES NO Installation Reservoir & Pump Connections The rear of the unit accepts various connections to integrate with your cooling system. IN/OUT: Liquid nozzle sockets POWER: Connection from power supply, 12VDC FAN: Radiator fan connections (2.0A max per plug, 3.
Fan Connection This unit has two connections to power radiator fans. Multiple fans can be combined into a single plug. (A fan wiring harness is optionally available from Koolance). ATX Pass-Through Lead ! CAUTION : The total combined amperage of all fans connected to the unit can not exceed 3A. The maximum load on a single fan header is 2.0A.
Nozzles Cooler & Tubing Configuration There are a vast number of methods for configuring a liquid cooling system (serial, parallel, combinations, alternating components, etc.). There is no single “correct” way! As long as coolant is flowing and you are satisfied with your device temperatures, it’s an acceptable configuration. Install the G 1/4 BSP threaded nozzles you purchased for your unit. It’s recommended to hand-tighten all fittings to avoid damaging the unit.
Disconnecting Hoses Parallel Loops Parallel loops are normally used to help accommodate water blocks with significantly disproportionate flow restriction. They can become quite complicated and if not well-planned, may lower performance through added bottlenecks and pressure drop. One suggestion for parallel loops is to reduce tubing size when splitting. Ideally, the hose area going into the splitter will be roughly equal to (or slightly lower than) the combined hose area coming out.
Liquid Coolers You should now install the liquid coolers (CPU, GPU, Hard Drive, etc.) to your hardware before continuing this User Manual. Please refer to your cooler kit’s individual installation instructions, then continue on to the next section. With the connected outlet hose, roughly estimate the length you will need to your first cooler, and cut it. Cut the second hose with enough length to reach the last water block that will be in your system.
Testing & Filling The cooling system should be powered on to assist in the filling process. This also allows you to check hose connections and make sure there are no tubing folds, leaks, or blockages. If cooling a computer, this can be done without powering on other hardware for extra safety (see below). Once all the water blocks have been connected, the system can be filled with coolant. The fill port is located on top of the reservoir. Free this component by removing its side drive screws.
Adding Coolers & Maintenance Troubleshooting With normal use, Koolance’s liquid coolant should be replaced every 2-3 years. If it ever becomes contaminated, unclear, or significantly changes color, it should be replaced immediately. A Koolance “drain valve” (sold separately) is recommended to make that process easier. We hope your Koolance system will provide you with years of reliable cooling performance.
this procedure may not be possible since there will be no visible air gap. 5. My system has boot-up problems, or does not turn on... Make sure the ATX wire lead is connected to “NO” (Normally Open) on the rear of the unit. (See: “Reservoir and Pump Connections” for details.) If this does not solve the issue, it is unrelated to the Koolance unit. In a computer, a problem with the RAM, motherboard, power supply, video card, processor, or monitor can cause the system to appear not to boot-up properly. 6.
Limited Warranty Koolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defects in materials or workmanship for a period of one year from the date of purchase, and agrees to repair or replace any defective Koolance system without charge. Shipping costs are non-refundable. This warranty is non-transferable. All warranty claims must be accompanied by the original proof of purchase.