Installation Guide

LP gas conversion:
IMPORTANT: Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified on the
model/serial rating plate for use with a dierent gas without consulting the serving
gas supplier. See “Gas Conversions” section.
GAS SUPPLY LINE
Provide a gas supply line of 3/4" (1.9 cm) rigid pipeo the range location. A smaller size
pipe on longer runs may result in insufficient gas sup y. Pipe-joint compounds that
resist the action of LP gas must be used. With LP gas, piping or tubing size can be 1/2
(1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in
the system.
Gas Shut-o Valve:
The gas supply line must be equipped with a manual shutoff valve. his valve
should be located in the same room but external to the range. It should be in a
location that allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas o the range.
a b c
a Gas Supply Line
b Shutoff Valve Open” Position
c Flexible/Rigid Gas Line to Range
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 - 5 ft (122 - 152.4 cm) long,
1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal applia onnector may be used
for connecting range to the gas supply line.
A 1/2" (1.3 cm) male pipe t ead is needed for connection to the female pipe
threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal ubing when moving the range.
13